Showing results 1 to 25 of 30
Search took 0.06 seconds.
Search: Posts Made By: dcam
Forum: LIVE PLC Questions And Answers February 28th, 2018, 02:00 PM
Replies: 7
Views: 554
Posted By dcam
Point or flex? that is the question.

I have always used flex I/O and have a new install at our plant that they are installing Point I/O. Can someone break down the pros and cons of each. Is it as easy to add I/O, the chassis looks like...
Forum: LIVE PLC Questions And Answers February 23rd, 2018, 02:41 PM
Replies: 6
Views: 572
Posted By dcam
All great responses! This is a remote I/O flex...

All great responses! This is a remote I/O flex rack with each module independently powered by a diff circuit for a peculiar E-stop MCR configuration and i believe the problem is here somehow. I...
Forum: LIVE PLC Questions And Answers February 23rd, 2018, 09:20 AM
Replies: 14
Views: 731
Posted By dcam
I have used a micrologix 1100 and a gecko drive...

I have used a micrologix 1100 and a gecko drive to run a stepper motor, worked perfectly.

https://www.geckodrive.com
Forum: LIVE PLC Questions And Answers February 23rd, 2018, 09:00 AM
Replies: 6
Views: 572
Posted By dcam
115vac outputs on unenergized dig ouput card

Hello all, struggling with an intermittent issue where i have 115VAC on outputs that are not energized(no light, not called for by program) . I've swapped output modules, changed the TB3 and cursed...
Forum: LIVE PLC Questions And Answers February 17th, 2018, 11:50 AM
Replies: 14
Views: 663
Posted By dcam
Check this company out: ...

Check this company out:
http://www.geckodrive.com/featured-products/gm215-step-motor-motion-controller-44.html

I did absorbing pad placer for poultry with this stepper controller
Forum: LIVE PLC Questions And Answers February 17th, 2018, 08:15 AM
Replies: 14
Views: 663
Posted By dcam
I think my micrologix 1100 has PTO out, this...

I think my micrologix 1100 has PTO out, this could be used, I think.
Forum: LIVE PLC Questions And Answers February 16th, 2018, 12:31 PM
Replies: 15
Views: 830
Posted By dcam
ifm effector has sensors that will do what you...

ifm effector has sensors that will do what you need and are decently priced, depending on the nature of the surface you are hitting ,laser would prob be best. dig out or 4-20. configurable
Forum: LIVE PLC Questions And Answers August 31st, 2017, 05:22 AM
Replies: 1
Views: 264
Posted By dcam
Abb control master cm30

Need to get into this CM30 at work. Password is lost. Anyone know a default or sevice password to use.

Thanks
Forum: LIVE PLC Questions And Answers August 14th, 2017, 07:46 AM
Replies: 2
Views: 294
Posted By dcam
power flex 70 programming issue

Had to replace a drive last night. I am having problems betting it running. I have installed many 700's and assumed the menu structure and set up was the same. using a 0-10 v analog speed ref (2) and...
Forum: LIVE PLC Questions And Answers January 24th, 2016, 08:44 PM
Replies: 5
Views: 653
Posted By dcam
thanks guys, gonna send it back. Its the first...

thanks guys, gonna send it back. Its the first time out of box that ive seen this type of failure. Was just checking that there wasnt a quick fix. Love this site.
Forum: LIVE PLC Questions And Answers January 24th, 2016, 06:07 AM
Replies: 5
Views: 653
Posted By dcam
We changed out HIM with no change......If we were...

We changed out HIM with no change......If we were to hook up with drive exec and found drive to be good, how would we fix HIM issue? New side board? HIM socket? Appreciate your response, thx.
Forum: LIVE PLC Questions And Answers January 24th, 2016, 05:22 AM
Replies: 5
Views: 653
Posted By dcam
Powerflex 700 issues

Just unpacked and installed a 15hp allen bradley powerflex 700 and its power cycling repeatedly. I have verified supply voltage and have no t leads connected. I think the vfd is bad out of box. This...
Forum: LIVE PLC Questions And Answers June 22nd, 2014, 06:41 PM
Replies: 3
Views: 642
Posted By dcam
sorry for the incomplete description. Had...

sorry for the incomplete description. Had equipment down. ended up being serial cable....was panicing. Thanks, you guys are great.
Forum: LIVE PLC Questions And Answers June 22nd, 2014, 01:18 PM
Replies: 3
Views: 642
Posted By dcam
Comm problems with SLC5-5

cannot establish comms with my slc-5 with rs 232 or rj 45???
Forum: LIVE PLC Questions And Answers May 26th, 2014, 01:30 AM
Replies: 1
Views: 1,119
Posted By dcam
Metler toledo IND560

Can some one tell me how to set up password access on this indicator. Thought it would be self explanitory, i have manual but it does not explain???:hmmm:
Forum: LIVE PLC Questions And Answers May 2nd, 2014, 10:27 AM
Replies: 3
Views: 509
Posted By dcam
old thread

How do i look up a old thread from 2012?
Forum: LIVE PLC Questions And Answers June 26th, 2012, 02:50 PM
Replies: 4
Views: 2,099
Posted By dcam
After starting the design process, We determined...

After starting the design process, We determined that mixing small and big boxes would not work for production. The case labeler is only capable of 16 small boxes a minute and large boxes would...
Forum: LIVE PLC Questions And Answers June 25th, 2012, 01:41 PM
Replies: 4
Views: 2,099
Posted By dcam
micro800 and Connected Components Workbench

Trying to implement the new Allen Bradely 800 series and its software, Connected Components Workbench here at the chicken plant in livingston ca. Does anyone know of training resources for CCW? Here...
Forum: LIVE PLC Questions And Answers June 25th, 2012, 01:25 PM
Replies: 13
Views: 9,572
Posted By dcam
micro810

We are trying to implement them here at Livingston Ca chicken land also. Here is a pict of a trainer we put together. Not much in terms of training resources, just a small utube stop light series....
Forum: LIVE PLC Questions And Answers June 13th, 2012, 10:47 AM
Replies: 24
Views: 3,851
Posted By dcam
thanks Lancie1 , i appreciate all the help i get...

thanks Lancie1 , i appreciate all the help i get from u guys.
Forum: LIVE PLC Questions And Answers June 12th, 2012, 04:07 PM
Replies: 24
Views: 3,851
Posted By dcam
yes im sorry....connected components workbench...

yes im sorry....connected components workbench and i have a micro810 on order .we used to only run big boxes on these lines. now production wants to run small boxes on line 1 and big boxes on line...
Forum: LIVE PLC Questions And Answers June 11th, 2012, 12:50 PM
Replies: 24
Views: 3,851
Posted By dcam
CCW Confusion

I'm trying to choreograph two inputs from photo eyes to control the timing of a conveyor brake which indexes boxes onto a dynamic weigh scale. Line one running small boxes (shorter brake release time...
Forum: LIVE PLC Questions And Answers April 19th, 2012, 02:38 PM
Replies: 18
Views: 3,437
Posted By dcam
had accel boost maxed from beginning, this was...

had accel boost maxed from beginning, this was first of 16 lines im upgrading ,expected bugs,next line will get 1/3 HP , that should fix issue i think???
Forum: LIVE PLC Questions And Answers April 19th, 2012, 01:46 PM
Replies: 18
Views: 3,437
Posted By dcam
lessened acceleration time and increased min freq...

lessened acceleration time and increased min freq to just under lowest operating freq. I think problem is gone.......thanks everyone.
Forum: LIVE PLC Questions And Answers April 18th, 2012, 01:34 PM
Replies: 18
Views: 3,437
Posted By dcam
these Marathon motors are cheap, thinku guys r...

these Marathon motors are cheap, thinku guys r right. gonna go to a third HP....once again u have all been a great help thx