Forum: LIVE PLC Questions And Answers November 16th, 2017, 04:26 PM
Replies: 10
Views: 310
Posted By ASF
I use VMWare and find it rock solid. Running on...

I use VMWare and find it rock solid. Running on an OSX host so I can't store my licenses on the host - I have a "main" Rockwell VM (Windows 7 64 bit) which has my activations, and if I need to use...
Forum: LIVE PLC Questions And Answers November 15th, 2017, 05:58 PM
Replies: 4
Views: 279
Posted By ASF
*Can* but probably *shouldn't*. There was a...

*Can* but probably *shouldn't*.

There was a thread about this exact topic a little while back - I'll see if I can find it - but the ultimate resolution was that yes, in very specific circumstances...
Forum: LIVE PLC Questions And Answers November 15th, 2017, 05:55 PM
Replies: 6
Views: 190
Posted By ASF
Just recently I was overseas in a plant with an...

Just recently I was overseas in a plant with an S7-300 PLC. One of those "wild frontier" countries that make you second guess everything you know about everything, because wierd s*** just keeps...
Forum: LIVE PLC Questions And Answers November 15th, 2017, 05:32 PM
Replies: 7
Views: 292
Posted By ASF
This is not correct - it's just that (as Rob...

This is not correct - it's just that (as Rob says) you have to delete the safety signature first. After that, you can do online edits.

Of course, one would never, ever do this on a system in...
Forum: LIVE PLC Questions And Answers November 13th, 2017, 09:04 PM
Replies: 21
Views: 665
Posted By ASF
I think all three of us are saying the same thing...

I think all three of us are saying the same thing - if you have to turn the "Siemens way of doing things" on it's head so that the end customer can have Bubba work on the machine without any extra...
Forum: LIVE PLC Questions And Answers November 13th, 2017, 06:46 PM
Replies: 21
Views: 665
Posted By ASF
Probably because their maintenance department is...

Probably because their maintenance department is primarily made up of high school dropouts and they refuse to give them any additional training (because training is expensive, as is hiring more...
Forum: LIVE PLC Questions And Answers November 9th, 2017, 05:12 PM
Replies: 4
Views: 298
Posted By ASF
Did you update the I/O hardware configuration in...

Did you update the I/O hardware configuration in the PLC? As sparkie says, if you post a copy of the program and highlight which module you replaced (and with what), we can probably do better than...
Forum: LIVE PLC Questions And Answers November 8th, 2017, 08:06 PM
Replies: 20
Views: 548
Posted By ASF
I had a look at the Sepasoft module. Looks really...

I had a look at the Sepasoft module. Looks really good, but $20k? Ouch!

I can see that at the right scale it would be massively worthwhile, but for a one-machine proof-of-concept starting point,...
Forum: LIVE PLC Questions And Answers November 8th, 2017, 05:38 PM
Replies: 17
Views: 544
Posted By ASF
I had it happen on a 1756-L71 running firmware...

I had it happen on a 1756-L71 running firmware v23.

I haven't exhaustively tested it across a lot of platforms, but something like that only ever bites me once :)
Forum: LIVE PLC Questions And Answers November 8th, 2017, 04:53 PM
Replies: 20
Views: 548
Posted By ASF
Thanks for the clarification Jesper. Siemens is...

Thanks for the clarification Jesper. Siemens is not my first language so I'm always on the learning curve with the Germans :)

There is not a huge amount of data required and there is no real...
Forum: LIVE PLC Questions And Answers November 8th, 2017, 04:48 PM
Replies: 17
Views: 544
Posted By ASF
A quick warning on this. Take the example of...

A quick warning on this.

Take the example of an array of DINT's, with 10 elements. Call it DINT_Array[0] through DINT_Array[9]. Let's say you call DINT_Array[Pointer].

If Pointer has a value of...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 09:45 PM
Replies: 12
Views: 193
Posted By ASF
I love cheap and nasty! I found those sort of...

I love cheap and nasty! I found those sort of things early on in my search, but unfortunately most of them are designed to just vent to atmosphere to relieve the pressure. Not quite the result I'm...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 09:39 PM
Replies: 20
Views: 548
Posted By ASF
Possibly, but at the moment the machines are...

Possibly, but at the moment the machines are "islands", each with their own (quite complex) profibus network. They're not interconnected. The thought of trying to merge them all into one profibus...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 09:24 PM
Replies: 12
Views: 193
Posted By ASF
Bingo! That's what I'm after. Thanks chelton!

Bingo! That's what I'm after. Thanks chelton!
Forum: LIVE PLC Questions And Answers November 7th, 2017, 09:03 PM
Replies: 12
Views: 193
Posted By ASF
True, and I initially tried that, but it wasn't...

True, and I initially tried that, but it wasn't as effective as I'd hoped. I have to put it right at the end of the watering lines or else the sections beyond that don't get the right pressure, and...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 08:57 PM
Replies: 12
Views: 193
Posted By ASF
I don't want the pressure to build up to cut-out...

I don't want the pressure to build up to cut-out pressure, that's the point. I want it to build up to around 150kPa and then stay there for as long as I have it set to water the plants. If I have two...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 08:54 PM
Replies: 12
Views: 193
Posted By ASF
No, it's an issue of tank size. This whole...

No, it's an issue of tank size.

This whole setup is on a high-rise balcony, and space is extremely limited. I don't have mains water available out there (and the cost to get it there is enormous...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 08:40 PM
Replies: 12
Views: 193
Posted By ASF
The one section in question is the section that's...

The one section in question is the section that's undercover. When it rains, everything else gets rained on, and I'm left with just needing to water this one little section on it's own.

I can...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 08:19 PM
Replies: 20
Views: 548
Posted By ASF
Thanks. At the moment, none of the PLC's are...

Thanks. At the moment, none of the PLC's are networked - they're all Profibus arrangements. So for each PLC I bring online, I'll have to add the lean ethernet module, and at that point I can start...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 08:14 PM
Replies: 12
Views: 193
Posted By ASF
OT: Pressure Relief Valve

Hi all,

A bit OT but hopefully a few of you will have come across what I'm after.

I have a ridiculously over-engineered watering system to water my balcony gardens, and when I'm only watering...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 08:02 PM
Replies: 20
Views: 548
Posted By ASF
Thanks Patrick. Good info, I'll give that some...

Thanks Patrick. Good info, I'll give that some thought. So presumably, I'd just need the OPC UA driver for Ignition, and a single Kepware license to run that way?

At the moment, it's all Siemens,...
Forum: LIVE PLC Questions And Answers November 7th, 2017, 05:28 PM
Replies: 20
Views: 548
Posted By ASF
Thanks guys. The comparative responses I have...

Thanks guys. The comparative responses I have from our Schneider rep and from Ignition are pushing me toward Ignition as well.

the_msp, can you give me any background as to why you'd go with...
Forum: LIVE PLC Questions And Answers November 5th, 2017, 10:43 PM
Replies: 20
Views: 548
Posted By ASF
I'm not sure if autocorrect got your last...

I'm not sure if autocorrect got your last sentence, or if it just went straight over my head ;)

The initial goal is mainly downtime tracking - whenever the machine is down, allow the operator to...
Forum: LIVE PLC Questions And Answers November 5th, 2017, 06:13 PM
Replies: 20
Views: 548
Posted By ASF
SCADA - Ignition vs Wonderware, Siemens S7-300 via Profibus

Hi all,

Got a client who has requested a SCADA system for downtime tracking and so on. Right now, they want to implement it as a standalone system on one machine, and then potentially expand out...
Forum: LIVE PLC Questions And Answers November 5th, 2017, 04:40 PM
Replies: 4
Views: 382
Posted By ASF
I saw an application once where the PanelView...

I saw an application once where the PanelView Plus was configured to display an alarm if the MicroLogix PLC was not in run mode.

The only thing was, they hadn't directly addressed the S bits...