Studio 5000 v33

Techguy

Member
Join Date
Oct 2021
Location
California
Posts
1
Hello everyone. I am trying to upload program from AB1768-L43 v16 to Studio 5000 v33 but I it indicates I need to install Logix Designer v16 to upload from this controller. Just installed Studio 5000 so not too familiar with it yet. I have used RSLogix 500 in the past. Thanks in advance.
 
That message is indicating that the processor is currently running v16 firmware and that to upload the program, you'll need RSLogix 5000 v16. The highest version of RSlogix 5000 (renamed Studio 5000 for versions higher) firmware that the L43 will accept is v20. These are different animals than the RS Logix 500 compatible processors.
 

Similar Topics

My current situation is a follows: I have two similar 1769 controllers with similar programs. Both have a UDT array that is being used to store...
Replies
6
Views
235
Hello Experts, I'm wondering if this has been done before if possible to create an Emulate file that have motion control axis? I tried to...
Replies
0
Views
142
Hi everyone: I need to upgrade my Studio 5000 to from V31 to V33, but when I try to download from Rockwell PCDC, I only have the option up to 31...
Replies
4
Views
1,384
Hello everyone, So I have an AOI that historizes data for the last 30 days, months and years. It worked fine for about a month, then I realized...
Replies
5
Views
1,363
Hello, I am having issues updating a studio 5000 file to V33. Its currently on V32. When I go into Properties>Change Controller>Software revision...
Replies
1
Views
1,039