Help with Indramat system200 and BTC06.

Join Date
Oct 2015
Location
Amsterdam
Posts
9
Hello Fellas,

We have a Rexroth BTC06.2A... handheld that needs to be programmed with a PPC-R01.2.
I'm a complete stranger in indramat, and Bosch Rexroth won't help us out :(

Is there somebody who would like to explain to me how I can create a program between the PPC and BTC06.
Or even better, is there training material somebody would like to share with me?

@ this point I'm trying to connect the BTC06 with the PPC without success.
My guess is that we have the wrong programming software (VisualMotion).
I've managed to get some files out of the handheld with ''Dolphi'', there all .bak files.
Which software is able to create/open these files?

Thanks in advance,
 
Why won't BR help?

Can you please quote the full Indramat part codes for the BTC & the PPC, better still would be pictures of the product labels.

How are they connected?

What is the application/machine?
 
The company I work for (Unis Group) specialises in the repair and sales of industrial electronics, so thats why BR won't help us ;)

The PCMCIA placed in the PPC has the following numbers:
• PSM01.1-FW
• MNR: R911280669-201
• FWB-PSM01*-GP*-08V58-MS
• MNR: R911290851-102
• SN: 289005-09898

The PPC unit has the following numbers:
• PPC-R01.2N-N-S1-FW
• SN: PPCR01-03226
• FWA-PPCR0*-GPP-08VRS-MS
• SN: 289005-00989

The BTC panel has the following numbers:
• Bootloader: BTC06*-DOL-01V11
• Software: BTC06*-SCM-03V01

VisualMotion
• VMT*PC-INB-08V10,WIN*32


We don't have a particular machine/application, I would like to test all the
functions on the BTC06 handheld to ensure it works well after repair.

Thanks in advance,
 
Thanks for the link, however I allready have this document.
If there is documentation about VisualMotion8 on how to program the BTC06 handheld, that would be great.
 

Similar Topics

Hi all, Am new here, normally I work on OSAI and Beckhoff systems but I have a problem with some Indramat dkc11.3 drives that all display the...
Replies
1
Views
1,405
I'm making some additions to an indramat MTX controlled machine and have added some faults in the logic but can't seem to find where the script...
Replies
0
Views
984
I'm stuck in a loop and need some help. Just got a used machine in with a s7 PLC and indramat CLC d02.3 motion control. I am not familiar with...
Replies
3
Views
2,571
Hello, I've got an Indramat Servo Drive that is a DKS 1.2-W100A-D base unit that has died on me. I have found quite a few DKS 1.1 floating...
Replies
0
Views
2,069
over the last year or so one of our best training customers has sent a lot of their technicians to us for Allen-Bradley PLC training ... now the...