Powerflex 525 - What would be the best way to reverse in RS Logix 5000

Join Date
Aug 2016
Location
Virginia
Posts
343
Good Evening ,

What would be the best way to reverse a motor using a Powerflex 525 drive in RS Logix 5000 ? The drive is running in one direction , but would like to reverse it, I'm using Ethernet and a CompactLogix . I took notice that the Forward and Reverse in the the outputs for forward and reverse are 0 , but it is still running . I took notice that the input from the drives for "Actual" direction is 1 . Would I force a 1 in the Forward or Reverse ?

Thanks for your help ,
 
put a 1 in ??:O.Reverse and it will go in reverse
to get it to go forward again you will need to take the 1 out of ??:O.Reverse and put a 1 into ??:O.Forward.

Alan