RSLogix 5000 Won't Open (Also Factory Talk View won't recognize activation)

nmurray

Member
Join Date
Apr 2014
Location
USA
Posts
90
So I had this problem last night, and could not find a fix anywhere on the internet.. Called Tech Support this morning such an easy fix I figured I would put it out there.. Will also help me so I can search it in the future if I forget.

My computer went to sleep then when I woke it up I could not open rslogix 5000.

I checked windows logger and saw an error with activations.

Went to C:\ProgramData\RockwellAutomation\FactoryTalkActivation\
Deleted all files in there. There may be 1 file that won't let you delete. Open task manager go to services and terminate anything that is rs5000.exe
Then finish deleting contents of the folder.
Restart system, everything started working as normal.
 
Thanks for all your help, deleting files in program data - Rockwell automation - Factory talk activation, and then there delete .rnl files after stopping rockwell processes in task manager was the solution for me (y)
 

Similar Topics

Hello, I am having a problem communicating with a RSLogix5000 program on a machine a usually do not have a problem connecting to. I am still a...
Replies
9
Views
3,226
Similiar to this thread: http://www.plctalk.net/qanda/showthread.php?t=91329 But I'm running 20.04 and had no issues till today. I'm going...
Replies
5
Views
14,127
Is this a bug in RSLogix 5000, or is there something wrong. I cannot get the TONR command to work in a sequential function chart; I can get it to...
Replies
17
Views
9,668
I'm getting the following error message on a file that I have been working on all day: Failed to open file 'C:\.....program_name.ACD'. Project...
Replies
12
Views
34,872
Back
Top Bottom