Old November 14th, 2017, 08:10 AM   #16
Phoenix11
Member
England

Phoenix11 is offline
 
Join Date: Oct 2017
Location: Wednesbury
Posts: 1
Quote:
Originally Posted by Max4507 View Post
Hi all!

I know I am bringing an old post back.. but I need to open an old Mitsubishi FX1N program which I think was programmed with Medoc!

Anyone still have the program?

Or even better, if someone is able to open my program backup, convert it, and send it back in a GX Developer version.. would be really appreciated.

Best regards,
As far as I recall, the final version of Medoc was version 2.41 and for quite a while was free of charge from Beijers Electronics. It actually comes as V.2.40 with 2.41 being an upgrade, of which I do have copies. I used Medoc for programming F1/F2, Fx, and A1S series PLC's.
  Reply With Quote
Old November 14th, 2017, 11:01 AM   #17
Andybr
Member
United Kingdom

Andybr is offline
 
Join Date: Oct 2004
Posts: 583
You should be able to import a Medoc programme directly into GX developer.
__________________
“What are the facts? Again and again and again-what are the facts? Shun wishful thinking, ignore divine revelation, forget what “the stars foretell,” avoid opinion, care not what the neighbors think, never mind the unguessable “verdict of history”–what are the facts, and to how many decimal places? You pilot always into an unknown future; facts are your single clue. Get the facts!”

Robert Heinlein.
  Reply With Quote
Old November 14th, 2017, 11:29 AM   #18
Ronnie Sullivan
Member
United Kingdom

Ronnie Sullivan is offline
 
Join Date: May 2010
Location: London
Posts: 376
Quote:
Originally Posted by Andybr View Post
You should be able to import a Medoc programme directly into GX developer.
Only if you checked the box to import medoc files at installation.

Zip or rar the files - post it on here, there are loads of people that will convert it to GX Dev format
  Reply With Quote
Old November 15th, 2017, 08:08 AM   #19
Sergei Troizky
Member
Canada

Sergei Troizky is offline
 
Join Date: Oct 2004
Location: Montreal
Posts: 688
Never did it myself, but recall mentioning that only Medoc 2.3 projects can be imported, but not 2.4. The reason being that the latter was not an official release by Mitsubishi, but Beijer's own development.
  Reply With Quote
Old November 22nd, 2017, 08:39 AM   #20
Max4507
Member
Canada

Max4507 is offline
 
Join Date: Feb 2016
Location: Québec
Posts: 29
Here is the files, any help with it will be gladly appreciated!!
Attached Files
File Type: zip BlisterMachine.zip (58.6 KB, 6 views)
  Reply With Quote
Old November 22nd, 2017, 09:38 AM   #21
Andybr
Member
United Kingdom

Andybr is offline
 
Join Date: Oct 2004
Posts: 583
GX_Dev_Project.zip
This is for GX Developer V8. I notice that it is very sparsely commented so good luck.
__________________
“What are the facts? Again and again and again-what are the facts? Shun wishful thinking, ignore divine revelation, forget what “the stars foretell,” avoid opinion, care not what the neighbors think, never mind the unguessable “verdict of history”–what are the facts, and to how many decimal places? You pilot always into an unknown future; facts are your single clue. Get the facts!”

Robert Heinlein.
  Reply With Quote
Old November 22nd, 2017, 09:59 AM   #22
Max4507
Member
Canada

Max4507 is offline
 
Join Date: Feb 2016
Location: Québec
Posts: 29
Quote:
This is for GX Developer V8. I notice that it is very sparsely commented so good luck.
Thanks you very much!! You are right, there is not that much comment. But it still better then the upload I had without any!

Thanks again!
  Reply With Quote
Old November 22nd, 2017, 05:02 PM   #23
Sergei Troizky
Member
Canada

Sergei Troizky is offline
 
Join Date: Oct 2004
Location: Montreal
Posts: 688
Here you are. The PLC in the project is FX2N.
The txt file is the ladder diagram. Very few devices names and comments.
There is no .dwr file for data memory content.
The .mpa file is for the Mitsubishi MTA-series display, but the project in it is empty.
Attached Images
File Type: jpg MTA.jpg (80.6 KB, 6 views)
Attached Files
File Type: txt ACULOGIX.TXT (152.3 KB, 5 views)

Last edited by Sergei Troizky; November 22nd, 2017 at 05:05 PM.
  Reply With Quote
Reply
Jump to Live PLC Question and Answer Forum

Bookmarks


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Similar Topics
Thread Thread Starter Forum Replies Last Post
Melsec Medoc Software cradle LIVE PLC Questions And Answers 13 June 15th, 2013 10:55 AM
Melsec Medoc. I know it's old, but... tony.del LIVE PLC Questions And Answers 3 September 21st, 2007 09:06 AM
Melsec Medoc installation problems zalmaflash LIVE PLC Questions And Answers 6 February 5th, 2007 11:45 AM
Where Can I get MELSEC MEDOC ?? markbray LIVE PLC Questions And Answers 3 November 5th, 2004 05:58 PM
Having problems printing in Melsec Medoc 1.6 Larssa_ LIVE PLC Questions And Answers 1 October 2nd, 2003 11:58 AM


All times are GMT -5. The time now is 11:55 AM.


.