chavn Lifetime Supporting Member C Join Date May 2017 Location Travelling Posts 8 May 26, 2017 #1 Hey there, I am having some issues displaying help files for AOI's in Logix5000. It tells me: """ Server Initialization Server did not load: "ASP.NET is not enabled or installed." """ I checked, and ASP.NET is installed under IIS. Anybody else had this issue?
Hey there, I am having some issues displaying help files for AOI's in Logix5000. It tells me: """ Server Initialization Server did not load: "ASP.NET is not enabled or installed." """ I checked, and ASP.NET is installed under IIS. Anybody else had this issue?
jkerekes Member Join Date Aug 2007 Location NJ Posts 2,362 May 26, 2017 #2 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/779298
chavn Lifetime Supporting Member OP C Join Date May 2017 Location Travelling Posts 8 May 27, 2017 #3 Thanks, I will check it out whenever I get my password.
Lovell Member Join Date Feb 2013 Location Saskatchewan, Canada Posts 120 Aug 9, 2018 #4 my solution I had this problem after installing RSLogix 5000 V20.04 in Windows 10 Pro. I did the following to fix it. Open CMD line with Admin rights: dism /online /enable-feature /all /featurename:IIS-ASPNET45 once its done, it should work.
my solution I had this problem after installing RSLogix 5000 V20.04 in Windows 10 Pro. I did the following to fix it. Open CMD line with Admin rights: dism /online /enable-feature /all /featurename:IIS-ASPNET45 once its done, it should work.
Ave Bender Member A Join Date Jun 2017 Location Saudi Arabia Posts 2 Feb 26, 2019 #5 @Lovell - Your command prompt enable for ASP.NET is really great. It worked for me. A million thanks, sir!
@Lovell - Your command prompt enable for ASP.NET is really great. It worked for me. A million thanks, sir!