Search: Posts Made By: PreLC
Forum: LIVE PLC Questions And Answers Yesterday, 01:56 PM
Replies: 5
Views: 195
Posted By PreLC
This is good info. So let's say I need a...

This is good info.
So let's say I need a standard 2000mm/s speed, with an acceleration of 1000mm/s^2.
Lets for this example, just assume that our ball screw's ratio is 360*=100mm, therefore...
Forum: LIVE PLC Questions And Answers Yesterday, 11:59 AM
Replies: 5
Views: 195
Posted By PreLC
How do you spec a motor+drive combo?

Hello PLCs.net!

I've worked with servos and robotics pretty often(guess not deep enough), but I've never really specced a drive+motor combo.

For this discussion, I would just like to specify a...
Forum: LIVE PLC Questions And Answers July 27th, 2021, 05:54 AM
Replies: 3
Views: 427
Posted By PreLC
Can you try taking the PWR OUT +24Vdc and PWR OUT...

Can you try taking the PWR OUT +24Vdc and PWR OUT COM from the power supply to the 3 screw terminals visible on the controller itself, right below the logo?

Page 64 of this manual has more info:...
Forum: LIVE PLC Questions And Answers July 17th, 2021, 01:53 PM
Replies: 7
Views: 750
Posted By PreLC
Have you tried to look installing the June Patch...

Have you tried to look installing the June Patch rollup?
Forum: LIVE PLC Questions And Answers July 16th, 2021, 09:00 PM
Replies: 20
Views: 2,668
Posted By PreLC
I remember being able to set up a depth in system...

I remember being able to set up a depth in system ferret, or am I imagining stuff from AssetCentre only?
Forum: LIVE PLC Questions And Answers July 16th, 2021, 06:44 PM
Replies: 20
Views: 2,668
Posted By PreLC
Not sure if this is what you want, but Rockwell...

Not sure if this is what you want, but Rockwell has a service called the system ferret tool(Free but erased from AB's downloads), or more recently the AssetInventory addon in Assetcentre. They can...
Forum: LIVE PLC Questions And Answers July 10th, 2021, 02:22 PM
Replies: 39
Views: 6,312
Posted By PreLC
Thanks for this! My 2010 Vaio VPCCA15FX will be...

Thanks for this! My 2010 Vaio VPCCA15FX will be void of a battery now, until I get a replacement.
Forum: LIVE PLC Questions And Answers July 8th, 2021, 09:54 AM
Replies: 4
Views: 556
Posted By PreLC
Any documentation for this? TCP/IP with Rockwell,...

Any documentation for this? TCP/IP with Rockwell, as well as for the printer?
Forum: LIVE PLC Questions And Answers July 7th, 2021, 04:24 PM
Replies: 4
Views: 556
Posted By PreLC
I see that natively it does not seem to have CIP,...

I see that natively it does not seem to have CIP, (https://www.evolabel.com/documentation/software-connectivity) , although it does have Modbus TCP, as well as digital I/O, among other options.
...
Forum: LIVE PLC Questions And Answers June 27th, 2021, 01:50 PM
Replies: 6
Views: 607
Posted By PreLC
It's actually available in "Extras", it's called...

It's actually available in "Extras", it's called a multiversion installer. They have one now which covers all PLCs from V20-33, available in the extras for V33.
Forum: LIVE PLC Questions And Answers June 24th, 2021, 10:30 AM
Replies: 14
Views: 1,068
Posted By PreLC
Maybe to get a random 50% occurrence?

Maybe to get a random 50% occurrence?
Forum: LIVE PLC Questions And Answers June 23rd, 2021, 09:40 AM
Replies: 10
Views: 1,133
Posted By PreLC
Wow I completely made the incorrect...

Wow I completely made the incorrect Flag+boolean->MB connection.
Definitely should be MX0.4, if it still doesn't work, then it's a different issue.
Forum: LIVE PLC Questions And Answers June 22nd, 2021, 02:04 PM
Replies: 10
Views: 1,133
Posted By PreLC
I'm looking here:...

I'm looking here: https://docs.inductiveautomation.com/display/DOC79/Siemens

Area: Flag
Datatype: Boolean
Offset: 4

So your address in ignition should be MB4.

Have you tried that yet?
Forum: LIVE PLC Questions And Answers June 22nd, 2021, 01:32 AM
Replies: 37
Views: 3,214
Posted By PreLC
Does this server have internet access? Updater...

Does this server have internet access? Updater might need to contact PCDC in order to get the latest software info.
Forum: LIVE PLC Questions And Answers June 22nd, 2021, 01:29 AM
Replies: 6
Views: 883
Posted By PreLC
You can also try navigating here: C:\Program...

You can also try navigating here:
C:\Program Files (x86)\Rockwell Software\Studio 5000\Logix Designer\ENU

and a similar extension for RSLogix5000, ENU folder.

This would have all installed...
Forum: LIVE PLC Questions And Answers June 18th, 2021, 12:10 PM
Replies: 11
Views: 2,294
Posted By PreLC
Can you give more details about your question? ...

Can you give more details about your question?

Are you trying to use the Factorytalk Activation manager hosted on a cloud? If not, can you give your architecture details and screenshots?

Also,...
Forum: LIVE PLC Questions And Answers June 17th, 2021, 10:21 AM
Replies: 4
Views: 478
Posted By PreLC
Seems like this program/routine you are working...

Seems like this program/routine you are working with is source protected, and unless you have the key, you would not be able to access it:...
Forum: LIVE PLC Questions And Answers June 15th, 2021, 05:34 PM
Replies: 37
Views: 3,214
Posted By PreLC
Just open the admin console on each computer, you...

Just open the admin console on each computer, you will have to access them individually unless your IT is competent and not just an army of apes(In that case, you might be able to read installed...
Forum: LIVE PLC Questions And Answers June 15th, 2021, 12:59 PM
Replies: 37
Views: 3,214
Posted By PreLC
All the versions you are looking at are for...

All the versions you are looking at are for different products.

From what I can tell, you have FTServicesPlatform V3, Diagnostics viewer V6.11 and RSLinx V4.0.

All of those have newer...
Forum: LIVE PLC Questions And Answers June 15th, 2021, 12:33 PM
Replies: 37
Views: 3,214
Posted By PreLC
I think you are at V3.0, based on your admin...

I think you are at V3.0, based on your admin console's version in the first shot.

The second shot only denotes the diagnostics viewer.
Forum: LIVE PLC Questions And Answers June 15th, 2021, 11:35 AM
Replies: 37
Views: 3,214
Posted By PreLC
Do you have a screenshot?

Do you have a screenshot?
Forum: LIVE PLC Questions And Answers June 15th, 2021, 10:46 AM
Replies: 37
Views: 3,214
Posted By PreLC
You can open the Factory talk Administration...

You can open the Factory talk Administration console and in help>about, you'll see the installed version.

Regards,
PreLC
Forum: LIVE PLC Questions And Answers June 9th, 2021, 08:51 PM
Replies: 14
Views: 874
Posted By PreLC
Do you have assetcenter? You should be able to...

Do you have assetcenter? You should be able to forward the audit logs from the HMI into the assetcentre server or a connected client device 11. It records all changes to the PLC tags and timestamp...
Forum: LIVE PLC Questions And Answers May 28th, 2021, 09:54 AM
Replies: 8
Views: 1,422
Posted By PreLC
You can use the RSLinx backup and restore utility...

You can use the RSLinx backup and restore utility to create RSLinx backups.

Alternatively, you can also dig into the drivers list registry, and copy and paste the list from there to sync your...
Forum: LIVE PLC Questions And Answers May 26th, 2021, 02:27 PM
Replies: 4
Views: 1,310
Posted By PreLC
Yes that should work out. We had remote OPC...

Yes that should work out.

We had remote OPC servers which acted partially like this. Have your networking team onboard so that networking issues can be worked out, but barring that, the...
Showing results 1 to 25 of 367

 