Search: Posts Made By: NetNathan
Forum: LIVE PLC Questions And Answers Yesterday, 06:06 AM
Replies: 32
Views: 887
Posted By NetNathan
I plan on retiring the end of this year. But my...

I plan on retiring the end of this year. But my life has been so involved with control and solving control problems, I fear it will be hard to leave.
Do you think about that end of retirement?
Forum: LIVE PLC Questions And Answers July 24th, 2021, 05:11 AM
Replies: 11
Views: 862
Posted By NetNathan
What PLC are you using? It may have a Function...

What PLC are you using? It may have a Function Block for Rate Of Change...
Forum: LIVE PLC Questions And Answers July 22nd, 2021, 10:33 PM
Replies: 28
Views: 3,539
Posted By NetNathan
Another kudo for Ignition is that it will work...

Another kudo for Ignition is that it will work with MySQL. Which can save some cost, since MySQL is free.
Forum: LIVE PLC Questions And Answers July 22nd, 2021, 10:25 PM
Replies: 14
Views: 1,046
Posted By NetNathan
Anywhere that you can get a Windows License that...

Anywhere that you can get a Windows License that uses a product key that can be validated is okay.
You will need an internet connection on your VM to validate the license, but that can be done after...
Forum: LIVE PLC Questions And Answers July 22nd, 2021, 10:00 PM
Replies: 14
Views: 1,046
Posted By NetNathan
When I do my VMs, I also do it as a standalone...

When I do my VMs, I also do it as a standalone version (which means you have to buy a Windows license for each one).
This way I can pass the VM to another person to run, good benefit if you do not...
Forum: LIVE PLC Questions And Answers July 22nd, 2021, 09:07 PM
Replies: 5
Views: 585
Posted By NetNathan
Then I would suggest contacting AVEVA tech...

Then I would suggest contacting AVEVA tech support in Singapore for fix.
Forum: LIVE PLC Questions And Answers July 22nd, 2021, 04:45 AM
Replies: 5
Views: 585
Posted By NetNathan
SO you originally had the License installed and...

SO you originally had the License installed and then you had to reinstall Windows and Intouch AND the license manager again? Now you get a message that the license is being used?
You may have to...
Forum: LIVE PLC Questions And Answers July 18th, 2021, 08:23 PM
Replies: 28
Views: 1,850
Posted By NetNathan
You also have to understand tag count. It may be...

You also have to understand tag count. It may be based on real IO but some SCADA systems count memory tags also.
Forum: LIVE PLC Questions And Answers July 12th, 2021, 09:15 AM
Replies: 12
Views: 1,126
Posted By NetNathan
Usually 4-20ma for control of valve. Flame...

Usually 4-20ma for control of valve.
Flame safety is for ignition system (pilot), not control of modulating valve for burner gas, but modulating valve must be FM approved. (like Honeywell valve...
Forum: LIVE PLC Questions And Answers July 11th, 2021, 10:39 PM
Replies: 4
Views: 572
Posted By NetNathan
Yes... I noticed that in the old manual also. ...

Yes... I noticed that in the old manual also. However I have done several Service requests and already found out it takes a transition coil to operate.
Forum: LIVE PLC Questions And Answers July 11th, 2021, 06:16 AM
Replies: 32
Views: 4,095
Posted By NetNathan
It is shame some of you do not have an In-N-Out...

It is shame some of you do not have an In-N-Out Burger nearby.
But now that starts and argument between Whopper and In-N-Out people...
Forum: LIVE PLC Questions And Answers July 11th, 2021, 02:21 AM
Replies: 4
Views: 572
Posted By NetNathan
You also mentioned "reset the fault"? What...

You also mentioned "reset the fault"?
What service request are you using? I am not aware you can "reset a fault" in 90-30 CPU, only clear all faults.
Forum: LIVE PLC Questions And Answers July 11th, 2021, 12:09 AM
Replies: 32
Views: 4,095
Posted By NetNathan
Good answer..

Good answer..
Forum: LIVE PLC Questions And Answers July 11th, 2021, 12:03 AM
Replies: 4
Views: 572
Posted By NetNathan
For service request 14 A "0" clears the PLC...

For service request 14
A "0" clears the PLC Fault table, and a "1' clears the IO Fault table.

Also have a pulse bit or one shot on the service request, you do not want to leave the "0" or "1"...
Forum: LIVE PLC Questions And Answers July 9th, 2021, 08:57 PM
Replies: 13
Views: 1,336
Posted By NetNathan
I am pretty sure the "brush connector" reduces...

I am pretty sure the "brush connector" reduces the enclosure rating to Nema1.
Forum: LIVE PLC Questions And Answers July 8th, 2021, 09:08 PM
Replies: 13
Views: 1,336
Posted By NetNathan
If you have a cooling fan and a separate filter...

If you have a cooling fan and a separate filter on the enclosure make sure fan is blowing into the cabinet and not out. That way you will not suck dust through the "wire brush" entry.
I have run...
Forum: LIVE PLC Questions And Answers July 2nd, 2021, 11:20 PM
Replies: 10
Views: 825
Posted By NetNathan
One of the most expensive logic programming...

One of the most expensive logic programming software packages available...
Studio 5000 Standard... just basic logic programming... almost $5K
Oh you want to do function blocks?... more money
Oh...
Forum: LIVE PLC Questions And Answers July 1st, 2021, 01:55 AM
Replies: 4
Views: 526
Posted By NetNathan
I would do the upload with the controller in stop...

I would do the upload with the controller in stop mode. That will make sure you get all CPU config data also. Sometimes an upload only uploads logic and not CPU cfg.
Forum: LIVE PLC Questions And Answers June 25th, 2021, 11:16 PM
Replies: 17
Views: 1,715
Posted By NetNathan
The system is under an Wonderware Intouch app. ...

The system is under an Wonderware Intouch app.
I am fully aware of verifying how the 2 communicate before editing, and Intouch does not communicate with the AB PLC tag names, only aliases and...
Forum: LIVE PLC Questions And Answers June 25th, 2021, 11:03 PM
Replies: 19
Views: 1,695
Posted By NetNathan
Did you try on more than 50 nodes? I think it...

Did you try on more than 50 nodes? I think it will work, they only would like you to buy to go over 50...
Forum: LIVE PLC Questions And Answers June 25th, 2021, 05:16 AM
Replies: 19
Views: 1,695
Posted By NetNathan
I am always stunned by the details from...

I am always stunned by the details from Slitheris.
AngryIP is really stripped down in comparison, plus you have to sometimes manually enter the IP range you want to scan. Slitheris lets you know...
Forum: LIVE PLC Questions And Answers June 25th, 2021, 12:31 AM
Replies: 17
Views: 1,715
Posted By NetNathan
Yes I found the tag I was looking for.. that was...

Yes I found the tag I was looking for.. that was actually easier than figuring out what is going on in the rest of the logic.
You are right, the logic is a total abomination..
It was converted from...
Forum: LIVE PLC Questions And Answers June 23rd, 2021, 08:51 AM
Replies: 8
Views: 788
Posted By NetNathan
Travel router plus! See my HooToo link..

Travel router plus! See my HooToo link..
Forum: LIVE PLC Questions And Answers June 23rd, 2021, 07:54 AM
Replies: 8
Views: 788
Posted By NetNathan
I really like my HooToo... does A LOT. (It is...

I really like my HooToo... does A LOT. (It is not as dedicated to Ipad/Iphone as it leads you to believe, works with my Android also...if you are wondering about that part of it).
Yes I also use as...
Forum: LIVE PLC Questions And Answers June 21st, 2021, 06:49 AM
Replies: 17
Views: 1,715
Posted By NetNathan
I thought I would have found some sort of...

I thought I would have found some sort of reference to rack and slot as I did with some of the other IO I was troubleshooting.