Forum: LIVE PLC Questions And Answers Today, 04:18 AM
Replies: 5
Views: 197
Posted By AlfredoQuintero
I would add that producer/consumer tags are also...

I would add that producer/consumer tags are also used to exchange information between IO such as EtherNet/IP or ControlNet adapters or DeviceNet slaves. These producer or consumer tags are associated...
Forum: LIVE PLC Questions And Answers Today, 04:11 AM
Replies: 3
Views: 150
Posted By AlfredoQuintero
I may not be understanding your problem very...

I may not be understanding your problem very well. I am curious: Are you running the engineering environment directly on the PLC? I have a Beckoff PLC with CFast card of only 8 GB. It is not possible...
Forum: LIVE PLC Questions And Answers Yesterday, 06:18 AM
Replies: 8
Views: 1,035
Posted By AlfredoQuintero
LadderLogic, John, hi. I am reviving this old...

LadderLogic, John, hi.
I am reviving this old post to report how I resolved my ordeal as well as to thank you for your input and finally, leave a record so it may help someone else.
I ended up...
Forum: LIVE PLC Questions And Answers June 13th, 2021, 01:22 AM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
Very interesting story. I have been to Mageburg...

Very interesting story. I have been to Mageburg twice, helping customers certify Profinet devices when ThorSys was called IFAK. Beautiful town. If I remember correctly, Fraunhofer has one of their...
Forum: LIVE PLC Questions And Answers June 12th, 2021, 05:32 PM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
danw, hello again. Quick update with...

danw, hello again.
Quick update with information which may not be news for you, but it was something I did not know about until just a few days ago.
...
Forum: LIVE PLC Questions And Answers June 7th, 2021, 08:55 AM
Replies: 19
Views: 962
Posted By AlfredoQuintero
I suspect the prefix K stands for "constant",...

I suspect the prefix K stands for "constant", because in Japanese "constant" would be written in Roman letters as "konsutansuto". Not sure if it is true but it is a rule for remembering when you see...
Forum: LIVE PLC Questions And Answers June 7th, 2021, 01:52 AM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
Thumbs up Yes, one would have thought there would be some...

Yes, one would have thought there would be some technotes so people can take interest in the technology. The only information that has some technical details as opposed to marketing mumbo-jumbo only...
Forum: LIVE PLC Questions And Answers June 6th, 2021, 03:19 AM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
Ken, Jesper and danw: I said I would provide...

Ken, Jesper and danw: I said I would provide follow-up on this issue. It seems that I will not be able get the 6ES7 134-6TD00-0CA1 so I will not be able to do the test of accessing HART variables...
Forum: LIVE PLC Questions And Answers June 5th, 2021, 08:24 PM
Replies: 6
Views: 492
Posted By AlfredoQuintero
Hi nuwan. I have been reading the technical...

Hi nuwan. I have been reading the technical documentation of this product and I cannot understand why it is showing E.7 which is poorly defined along with E.5, E.6 and E.CPU as internal CPU...
Forum: LIVE PLC Questions And Answers June 5th, 2021, 06:59 AM
Replies: 6
Views: 492
Posted By AlfredoQuintero
Hello: This error will be generated when the...

Hello:
This error will be generated when the communication between the PLC and the fr-f740-00470-ec and the Mitsubishi PLC is not working. I checked the manual as I am not familiar with this VFD,...
Forum: LIVE PLC Questions And Answers June 3rd, 2021, 05:23 AM
Replies: 3
Views: 274
Posted By AlfredoQuintero
As suggested in the screenshot you have posted,...

As suggested in the screenshot you have posted, it seems there is an issue with the program itself. It may be some very rare state for the program which only happens under very special circumstances,...
Forum: LIVE PLC Questions And Answers June 1st, 2021, 10:50 PM
Replies: 4
Views: 265
Posted By AlfredoQuintero
I do not know if it is possible to just reset the...

I do not know if it is possible to just reset the password without doing a factory default reset. I found a post in reddit but you need to have another switch for which you do know the password so...
Forum: LIVE PLC Questions And Answers June 1st, 2021, 07:00 PM
Replies: 4
Views: 265
Posted By AlfredoQuintero
Welcome to the forum. The documentation for...

Welcome to the forum.
The documentation for Stratix describes this procedure. Good luck.
Forum: LIVE PLC Questions And Answers June 1st, 2021, 01:59 PM
Replies: 4
Views: 389
Posted By AlfredoQuintero
I think you can get the firmware version with the...

I think you can get the firmware version with the Siemens free tool called PRONETA, which can be downloaded from their website.
Forum: LIVE PLC Questions And Answers June 1st, 2021, 01:56 PM
Replies: 15
Views: 1,147
Posted By AlfredoQuintero
I read in some article years ago about a company...

I read in some article years ago about a company whose motto was "we make free software affordable".
Forum: LIVE PLC Questions And Answers June 1st, 2021, 01:51 PM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
But have you ever seen someone trying to read...

But have you ever seen someone trying to read variables other than process value and not succeeding, or is it that those who need those variables use the PDM add on, without attempting to write the...
Forum: LIVE PLC Questions And Answers June 1st, 2021, 12:16 AM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
danw: I share the same feeling. For over 30 years...

danw: I share the same feeling. For over 30 years most PLC applications use only cyclic communication to get process data and the acyclic stuff is for the HMI, SCADA or "Asset Management" software...
Forum: LIVE PLC Questions And Answers June 1st, 2021, 12:02 AM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
JesperMP & danw, thanks very much for taking the...

JesperMP & danw, thanks very much for taking the time to find this information for me. I need to go through (and I will, for sure) this documentation, but it does seem to be possible to encapsulate...
Forum: LIVE PLC Questions And Answers May 31st, 2021, 03:23 AM
Replies: 14
Views: 1,088
Posted By AlfredoQuintero
Is it possible to send generic HART commands with 6ES7 134-6TD00-0CA1(Siemens AI 4xI?

Hello:
Just posted a similar inquiry with regards to Rockwell HART master. Trying to figure out whether the Siemens offering is better.
I need to do a feasibility study for a project that needs to...
Forum: LIVE PLC Questions And Answers May 31st, 2021, 01:47 AM
Replies: 1
Views: 320
Posted By AlfredoQuintero
Just realized that the 1756-IF16H/A has 16...

Just realized that the 1756-IF16H/A has 16 channels and up to 16 of them can be connected to a 1756-EN2T coupler. Same question, is it possible to send generic HART commands with this product?
Forum: LIVE PLC Questions And Answers May 31st, 2021, 01:13 AM
Replies: 1
Views: 320
Posted By AlfredoQuintero
Is it possible to send generic HART commands with 1794-IE8H?

https://literature.rockwellautomation.com/idc/groups/literature/documents/um/1794-um063_-en-p.pdf
Hello. Trying to figure out if it would be possible to use 1794-IE8H in order to send generic HART...
Forum: LIVE PLC Questions And Answers May 29th, 2021, 10:30 PM
Replies: 32
Views: 2,762
Posted By AlfredoQuintero
If the PC has anti-virus software, perhaps you...

If the PC has anti-virus software, perhaps you can try adding Logix Studio to the exception list of the anti-virus software.
Forum: LIVE PLC Questions And Answers May 29th, 2021, 10:25 PM
Replies: 32
Views: 2,762
Posted By AlfredoQuintero
Are you able to launch the FactoryTalk Activation...

Are you able to launch the FactoryTalk Activation Manager?
Forum: LIVE PLC Questions And Answers May 29th, 2021, 07:56 PM
Replies: 32
Views: 2,762
Posted By AlfredoQuintero
Did you try launching as Administrator?

Did you try launching as Administrator?
Forum: LIVE PLC Questions And Answers May 28th, 2021, 06:26 PM
Replies: 4
Views: 540
Posted By AlfredoQuintero
How long is the cable? Are you using terminator...

How long is the cable? Are you using terminator resistors? Are you using shielded cable?