Search: Posts Made By: davejc
Forum: LIVE PLC Questions And Answers April 9th, 2021, 11:07 AM
Replies: 17
Views: 793
Posted By davejc
Just to close the loop here.... What I ended...

Just to close the loop here....

What I ended up with is:

Tag: PartString.Part_X_Str is my actual string tag. There are 48 of these.

Tag: PartBit.Part_X_Bit0 has its source...
Forum: LIVE PLC Questions And Answers April 9th, 2021, 10:03 AM
Replies: 17
Views: 793
Posted By davejc
FOr whatever reason, taking it out of teh array...

FOr whatever reason, taking it out of teh array and making it 4 separate tags works.

No idea why, but it works
Forum: LIVE PLC Questions And Answers April 9th, 2021, 08:29 AM
Replies: 17
Views: 793
Posted By davejc
making some progress. The packed bit shows...

making some progress.

The packed bit shows up as expected. But, Kep only wants to read the first bit of the array. Not sure why that is the case.
Forum: LIVE PLC Questions And Answers April 9th, 2021, 07:07 AM
Replies: 17
Views: 793
Posted By davejc
Thank you for the explanation. Makes sense the...

Thank you for the explanation. Makes sense the way you explain it. I am new to a lot of this type of stuff.

Heading back to customer this morning and will see how it goes. I am confident tho.
Forum: LIVE PLC Questions And Answers April 8th, 2021, 09:09 PM
Replies: 17
Views: 793
Posted By davejc
I guarantee Im not doing this right, but I am at...

I guarantee Im not doing this right, but I am at least getting what I expect on the packed bits.
Forum: LIVE PLC Questions And Answers April 8th, 2021, 08:54 PM
Replies: 17
Views: 793
Posted By davejc
so in this case, tag3=84, tag4=70 ...

so in this case, tag3=84, tag4=70
(tag3<<8)+tag4 = 21574

shouldnt it be 8470 ??
Forum: LIVE PLC Questions And Answers April 8th, 2021, 07:06 PM
Replies: 17
Views: 793
Posted By davejc
It would be nice if Red Lion would help. They...

It would be nice if Red Lion would help. They don't want to help because I am using Honeywell's version of the G3. Of course, Honeywell is no help either.

I can convert individual characters to...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 06:25 PM
Replies: 17
Views: 793
Posted By davejc
Yea, thats where I got lost is he doesnt show...

Yea, thats where I got lost is he doesnt show CharToAscii.

If you have some tips that would be fantastic. Its the last thing I need to do on this project.
Forum: LIVE PLC Questions And Answers April 8th, 2021, 04:22 PM
Replies: 17
Views: 793
Posted By davejc
Convert String to PackBit in Redlion G3

First post here, hopefully not breaking any rules.

I am working with a Redlion G3 HMI (yes, I know). I have a series of string tags that I am trying to communicate over modbus to a kepware OPC...