Search: Posts Made By: Tim Ganz
Forum: LIVE PLC Questions And Answers April 26th, 2021, 02:20 AM
Replies: 2
Views: 360
Posted By Tim Ganz
Weird Fault on MicroLogix 1400

I have a fault on a micrologix 1400 that says" The controller cannot communicate with an expansion i/o module. The exact module cannot be determined"

If it doesn't know which module how does it...
Forum: LIVE PLC Questions And Answers April 19th, 2021, 12:40 AM
Replies: 7
Views: 752
Posted By Tim Ganz
Cooling Options

I have to build a new cabinet to house a 22-inch touch screen, Mini PC, Panel Mount UPS, Ethernet Switch.

It will be in an area that is extremely dusty but the area is air-conditioned so I am not...
Forum: LIVE PLC Questions And Answers April 12th, 2021, 02:27 AM
Replies: 17
Views: 1,262
Posted By Tim Ganz
How do you know what the correct version is from...

How do you know what the correct version is from the .acd file?
Forum: LIVE PLC Questions And Answers April 9th, 2021, 10:58 AM
Replies: 21
Views: 1,037
Posted By Tim Ganz
Found an old laptop with the development software...

Found an old laptop with the development software also as well as runtime license.

Can I restore the project to this laptop and make changes and export from laptop and back to server without...
Forum: LIVE PLC Questions And Answers April 9th, 2021, 01:09 AM
Replies: 3
Views: 395
Posted By Tim Ganz
Ken Are these different from the Panelview...

Ken

Are these different from the Panelview 1200 E? How so?

BTW thanks for posting this. I love learning the history and more about the older gear because in the field you come across it more...
Forum: LIVE PLC Questions And Answers April 9th, 2021, 01:06 AM
Replies: 21
Views: 1,037
Posted By Tim Ganz
The PLC programs that are Logix have the tags as...

The PLC programs that are Logix have the tags as Station1_Primary_Pump_Start and so on with that can I export the tags from the Logix program and export the tag DB from Rs View 32 and make the...
Forum: LIVE PLC Questions And Answers April 9th, 2021, 01:01 AM
Replies: 21
Views: 1,037
Posted By Tim Ganz
There are lots of project directories with the...

There are lots of project directories with the same name but v1, v2 etc.

How can I tell which one is the active production running project?
Forum: LIVE PLC Questions And Answers April 8th, 2021, 05:46 PM
Replies: 17
Views: 1,262
Posted By Tim Ganz
Just for curiousity where do you find this option?

Just for curiousity where do you find this option?
Forum: LIVE PLC Questions And Answers April 8th, 2021, 05:44 PM
Replies: 21
Views: 1,037
Posted By Tim Ganz
Yes I have seen .RVS mentioned when searching...

Yes I have seen .RVS mentioned when searching online but did not find a lot of detail.

It will be a flash drive or usb removable drive. The IT guy has several sizes of usb external drives and...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 05:16 PM
Replies: 21
Views: 1,037
Posted By Tim Ganz
That it does and ControlNet as well. Most of the...

That it does and ControlNet as well. Most of the PLC 5 stuff is DH+ and the SLC units are Controlnet and then there are lots of compact logix and controllogix on ethernet.

It has a quad ethernet...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 04:15 PM
Replies: 5
Views: 481
Posted By Tim Ganz
Panelview Standard DF1 Vs ControlLogix DF1

Does anyone know if panelview standard DF1 Vs controlLogix DF1are the same cable / pinout?

I have a 1756-CP3 and trying to use it on a Panelview 1000 standard to download a program using the rs...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 04:02 PM
Replies: 21
Views: 1,037
Posted By Tim Ganz
There is also a note in the documentation from...

There is also a note in the documentation from the previos PLC guy that they added logic in the PLC to prevent HMI buttons sticking? Says added logicc to unlatch HMI buttons?
Forum: LIVE PLC Questions And Answers April 8th, 2021, 04:00 PM
Replies: 21
Views: 1,037
Posted By Tim Ganz
I assume you mean the windows file directory?...

I assume you mean the windows file directory? Will this capture everything?

I ask because we have the RS View 32 install disks and I really want to move it to a better piece of hardware but it has...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 03:54 PM
Replies: 21
Views: 1,037
Posted By Tim Ganz
What file type would this method create?

What file type would this method create?
Forum: LIVE PLC Questions And Answers April 8th, 2021, 03:53 PM
Replies: 21
Views: 1,037
Posted By Tim Ganz
Its a RS View 32 app that runs on a PC versus a...

Its a RS View 32 app that runs on a PC versus a panelview. We have panel bulider 32 for our panelview standar units / the black case type.
Forum: LIVE PLC Questions And Answers April 8th, 2021, 01:42 PM
Replies: 21
Views: 1,037
Posted By Tim Ganz
RS View 32 Making Changes

I have to make some additions to an RS View 32 system and I have never worked with it and have not found many training or other resources on it. It seems to be very close to FT View SE?

It...
Forum: LIVE PLC Questions And Answers April 1st, 2021, 06:16 PM
Replies: 4
Views: 413
Posted By Tim Ganz
2711-B5A1 is the right number. I guess i have to...

2711-B5A1 is the right number. I guess i have to connect to this with one of the old PIC boxes?

Also i have some 1747-SN modules for blue hose can that be configured to talk to the panelview over...
Forum: LIVE PLC Questions And Answers April 1st, 2021, 05:49 AM
Replies: 5
Views: 631
Posted By Tim Ganz
Thanks all

Thanks all
Forum: LIVE PLC Questions And Answers March 28th, 2021, 11:08 PM
Replies: 5
Views: 631
Posted By Tim Ganz
Firmware Questions

I have an L72 processor that says firmware upgrade needed on the screen and llynx says it has 1.8 installed. If I flash to like V21 or something can I down flash it back to 1.8 or something close?
...
Forum: LIVE PLC Questions And Answers March 28th, 2021, 11:04 PM
Replies: 4
Views: 413
Posted By Tim Ganz
PV Cable

I have a panelview 2711-B5A1 that we need to connect to a slick 5/02 application and I can't seem to determine what cable I need to make or buy and I am looking for some direction?
Forum: LIVE PLC Questions And Answers March 1st, 2021, 11:11 AM
Replies: 5
Views: 598
Posted By Tim Ganz
How does this follow in Controllogix? I have some...

How does this follow in Controllogix? I have some ControlLogix machines with eNBT cards and some will show with the ethernet IP driver and some just won't but the units that won't show wit the...
Forum: LIVE PLC Questions And Answers February 9th, 2021, 09:37 PM
Replies: 3
Views: 448
Posted By Tim Ganz
Studio 5000 File Opening Issue

installed all versions of studio 5000 21-32 and trying to open a v28 file but it tries to open in 32 and gives me an error that the file was created in a newer version?

Not sure how to tackle this.
Forum: LIVE PLC Questions And Answers February 9th, 2021, 09:14 PM
Replies: 8
Views: 885
Posted By Tim Ganz
I think you may be on to something there.

I think you may be on to something there.
Forum: LIVE PLC Questions And Answers February 9th, 2021, 02:52 PM
Replies: 8
Views: 885
Posted By Tim Ganz
From my OP and as OkiePC said the DVDs do have a...

From my OP and as OkiePC said the DVDs do have a tick box to install previous versions. I was ,making a statement on that not a question as I have done it many times that way at my previous employer....
Forum: LIVE PLC Questions And Answers February 6th, 2021, 06:20 PM
Replies: 8
Views: 885
Posted By Tim Ganz
RS Logix 5000 and Studio 5000 DVD

When i purchased boxed software in the past the RS Logix 5000 and Studio 5000 DVD had all versions on it and when you installed you could check a box and it would install all the versions.

All I...
Showing results 1 to 25 of 500

 