You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 500
Search took 0.34 seconds.
Search: Posts Made By: Jeebs
Forum: LIVE PLC Questions And Answers March 16th, 2021, 07:45 AM
Replies: 7
Views: 1,089
Posted By Jeebs
These values are found in the Object Viewer. ...

These values are found in the Object Viewer.

In the ArchestrA IDE, find your engine. Right click on it and select "View in Object Viewer".
It will open the Object Viewer. In the left pane check...
Forum: LIVE PLC Questions And Answers March 16th, 2021, 06:25 AM
Replies: 35
Views: 4,395
Posted By Jeebs
I checked the ad for the position I was about to...

I checked the ad for the position I was about to vacate at my previous job. They had no clue. The ad was so bad, even I wouldn't have made it through the first round of the application process.
Forum: LIVE PLC Questions And Answers March 15th, 2021, 05:49 AM
Replies: 7
Views: 1,089
Posted By Jeebs
Is that a typo for topic 3 or is it actually...

Is that a typo for topic 3 or is it actually configured for 10003ms?

You'd want your topics to have differing intervals, best practice is prime numbers around the expected update cycle. This to...
Forum: LIVE PLC Questions And Answers March 11th, 2021, 03:38 AM
Replies: 2
Views: 515
Posted By Jeebs
I got it. One of my addons wasn't playing nice on...

I got it. One of my addons wasn't playing nice on their site. Didn't give me the proper drop downs in the selection tool. Couldn't see the memory selection for instance. Once that was fixed I got the...
Forum: LIVE PLC Questions And Answers March 10th, 2021, 09:57 AM
Replies: 2
Views: 515
Posted By Jeebs
Rockwell compatibility matrix for older systems

Hi,

I'm looking for the older style compatibility matrix Rockwell used to have which lists which CPU's are compatible with which ENET/CNET card versions.

The system I need to check still has...
Forum: LIVE PLC Questions And Answers January 14th, 2020, 09:27 AM
Replies: 10
Views: 1,352
Posted By Jeebs
Do you mean in runtime or the IDE?

Do you mean in runtime or the IDE?
Forum: LIVE PLC Questions And Answers December 19th, 2019, 10:57 AM
Replies: 2
Views: 604
Posted By Jeebs
:banghead::banghead::banghead::banghead: As...

:banghead::banghead::banghead::banghead:

As I said. Ridiculously simple.

Thank you. :beer:
Forum: LIVE PLC Questions And Answers December 19th, 2019, 10:47 AM
Replies: 2
Views: 604
Posted By Jeebs
Logix Designer: Routing via L83ES

Hi,

I have a machine set up with a L83ES and a ENBT/A Ethernet card in the rack. Ethernet card is connected to plant network. L83ES internal Ethernet is connected to various IO's, drive, PV's and...
Forum: LIVE PLC Questions And Answers November 4th, 2019, 04:11 AM
Replies: 4
Views: 1,124
Posted By Jeebs
Software bought through (very unhelpful) OEM, no...

Software bought through (very unhelpful) OEM, no direct contact with Rockwell rep. Trying to find contact info through Rockwell site is how I've wasted 1 of those 3 hours.
Forum: LIVE PLC Questions And Answers November 4th, 2019, 04:02 AM
Replies: 4
Views: 1,124
Posted By Jeebs
Rockwell: Any way to request software version change from Rockwell?

Short story:

New machine, new software versions. Request new engineering software. Requested 9701-VWSTMENE. Received 9701-VWSTMINTL. The latter has only French or German as available languages.
...
Forum: LIVE PLC Questions And Answers November 4th, 2019, 03:05 AM
Replies: 33
Views: 5,674
Posted By Jeebs
There isn't one unifying system used in Europe. ...

There isn't one unifying system used in Europe.

For instance we have several machines where the wires have different numbers on both ends. To signify where they are going to. Wow, great, right?...
Forum: LIVE PLC Questions And Answers March 28th, 2019, 04:10 AM
Replies: 4
Views: 855
Posted By Jeebs
TAK is just swapping ACCU1 with ACCU2. Values...

TAK is just swapping ACCU1 with ACCU2. Values from ACCU1 goes to ACCU2 and values from ACCU2 goes to ACCU1. Important for - and / calculations, not so much for + and *.
Code needs optimization tbh....
Forum: LIVE PLC Questions And Answers March 27th, 2019, 04:01 AM
Replies: 7
Views: 986
Posted By Jeebs
Ken meant 65 for A to F

Ken meant 65 for A to F
Forum: LIVE PLC Questions And Answers March 13th, 2019, 04:52 AM
Replies: 67
Views: 10,426
Posted By Jeebs
I'd wear this one. Every day. Just so I can point...

I'd wear this one. Every day. Just so I can point at it in stead of repeating myself.
Forum: LIVE PLC Questions And Answers March 11th, 2019, 05:56 AM
Replies: 14
Views: 1,651
Posted By Jeebs
Profinet is local. Should remain local. Always. ...

Profinet is local. Should remain local. Always.

We add network cards for plant networks. Or use multi-network cards if possible.

In your case, we'd leave the CPU and drive on local island, then...
Forum: LIVE PLC Questions And Answers February 28th, 2019, 10:57 AM
Replies: 12
Views: 2,320
Posted By Jeebs
Rockwell really needs to get with the times. But...

Rockwell really needs to get with the times. But I guess why do the engineering from free when you can get license fee's from 3rd party vendors?

With a compatible card you'd need like 5 or 6 MSG...
Forum: LIVE PLC Questions And Answers February 7th, 2019, 07:20 AM
Replies: 21
Views: 2,492
Posted By Jeebs
Have you tried turning it CCW?

Have you tried turning it CCW?
Forum: LIVE PLC Questions And Answers January 9th, 2019, 07:51 AM
Replies: 11
Views: 981
Posted By Jeebs
Have you looked into RD_REC and WR_REC. With...

Have you looked into RD_REC and WR_REC. With these you can achieve what you wish, creating a fully dynamic FB with dynamic configuration possibility for connected devices. With this you shouldn't...
Forum: LIVE PLC Questions And Answers December 12th, 2018, 08:24 AM
Replies: 12
Views: 1,530
Posted By Jeebs
My apologies if my comment looked rather harsh....

My apologies if my comment looked rather harsh. When I was typing my reply your comment about getting it to work wasn't there yet. I got called away before I could finish it and hit Submit Reply much...
Forum: LIVE PLC Questions And Answers December 11th, 2018, 10:58 AM
Replies: 12
Views: 1,530
Posted By Jeebs
Tbh, the solution to your issue was given twice...

Tbh, the solution to your issue was given twice in the 2 posts following your initial post.
Forum: LIVE PLC Questions And Answers December 6th, 2018, 03:25 AM
Replies: 16
Views: 3,013
Posted By Jeebs
New with just TIA or Siemens HMI's in general? ...

New with just TIA or Siemens HMI's in general?

This is THE golden rule when working with Siemens HMI's, it'll save you hours upon hours upon hours of frustration. You better make this a habit now....
Forum: LIVE PLC Questions And Answers November 28th, 2018, 06:44 AM
Replies: 1
Views: 639
Posted By Jeebs
2711P-T12W22D9P - 2 Eth ports switch or individual ports?

Since the documentation doesn't specify, the 2 ethernet ports on Panel mentioned in title, is it a 2-port switch or 2 individual ports with separate addresses/coms/etc?
Forum: LIVE PLC Questions And Answers November 15th, 2018, 02:58 AM
Replies: 28
Views: 3,222
Posted By Jeebs
Should not ignore/dismiss information just...

Should not ignore/dismiss information just because you dislike it. What is shown is exactly what his source is referring to.
Forum: LIVE PLC Questions And Answers November 14th, 2018, 10:40 AM
Replies: 28
Views: 3,222
Posted By Jeebs
Seems to be lacking some...

Seems to be lacking some information/understanding here.

What is a FB?

A FB is a block which can have a instance DB connected to it. When you create IN/OUT/IN_OUT/STAT variables, then that FB...
Forum: LIVE PLC Questions And Answers October 29th, 2018, 08:26 AM
Replies: 23
Views: 3,602
Posted By Jeebs
Both KTP and S7 can be back-up and copied. You...

Both KTP and S7 can be back-up and copied. You can lock it so it can't be changed, but you cannot lock it so it can't be cloned.
Showing results 1 to 25 of 500

 
Forum Jump

All times are GMT -4. The time now is 08:36 AM.


.