Forum: LIVE PLC Questions And Answers April 28th, 2021, 02:48 AM
Replies: 0
Views: 234
Posted By Oliver Micka
2080-LC30-24QWB - firmware download failed

Hi all,
I have problem with this PLC.
I have Micro 830 ( 2080-LC30-24QWB series A ).
Yesterday i tried download PLC code in to the PLC,
CCW wanted to upgrade firmware on this PLC,

I did chose...
Forum: LIVE PLC Questions And Answers April 27th, 2021, 08:53 AM
Replies: 2
Views: 307
Posted By Oliver Micka
Nobody know?

Nobody know?
Forum: LIVE PLC Questions And Answers April 26th, 2021, 08:31 AM
Replies: 2
Views: 307
Posted By Oliver Micka
AB Micro 830 and Kinco HMI

Hi, Its possible communicate between kinco hmi (mt4404t) and Micro830 through a serial line ( rs232/485 ) ?
Forum: LIVE PLC Questions And Answers April 13th, 2021, 04:56 AM
Replies: 0
Views: 213
Posted By Oliver Micka
Pv800 + dh485 + 1747-aic

Hi,
I have SLC 5/03 with 1747-AIC (DH485) modules. Original HMI was PV550, this HMI was replaced to a PanelView 800 (2711R-T7T), communicating is throught DH485 (DHX2 port).
I have problem with...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 09:17 AM
Replies: 0
Views: 194
Posted By Oliver Micka
Micro 820 -DeviceNet - Slave

Hi, I need help,
It is possible use to Micro820 with 2080-DNET20 than to Slave I/O ?
If i Add 2080-DNET in to the RsNetworx(DNET), I dont seen this card in to the Main DeviceNet scanner. ( Scanlist...
Forum: LIVE PLC Questions And Answers January 8th, 2021, 07:46 AM
Replies: 0
Views: 432
Posted By Oliver Micka
Kinco HMI and S7-1200 (RS485)

Hi all.
Are someone was tried to connect HMI with only serial port ( rs232/485 ) to a PLC (S7-1200 + CM 1241 RS485 )
I have a machine, where is a several Kinco HMI ( MT4404T - comm throught RS485...
Forum: LIVE PLC Questions And Answers December 22nd, 2020, 10:34 AM
Replies: 2
Views: 813
Posted By Oliver Micka
Micro 820 - HSC

Hi all.
Does anybody know, is Micro 820 ( 2080-LC20-20QBB ) have a directly HSC inputs ?
I would like connect two "encoders" to the Micro 820 and read data from this.
I found video on a Youtube...
Forum: LIVE PLC Questions And Answers December 11th, 2020, 02:09 AM
Replies: 4
Views: 884
Posted By Oliver Micka
I have tested MSG config for L33/L36, i believe...

I have tested MSG config for L33/L36, i believe that is the same config for all Logix CPU family. That is why i used the same config for proccessor L35e.
Nothing.
I tried use many address for a...
Forum: LIVE PLC Questions And Answers December 10th, 2020, 10:59 AM
Replies: 4
Views: 884
Posted By Oliver Micka
CompactLogix L35e and Micro 820/850

Hi all.
I need litle help.
I need connected Micro 850 ( 2080-LC50-24QWB) to a Main PLC (CompactLogix L35e) and send/recieve data throught Ethernet.
I have a several informtion : How make it.
In...
Forum: LIVE PLC Questions And Answers October 7th, 2020, 08:04 AM
Replies: 5
Views: 583
Posted By Oliver Micka
Nope, WinRar cannot open this file

Nope, WinRar cannot open this file
Forum: LIVE PLC Questions And Answers October 7th, 2020, 07:27 AM
Replies: 5
Views: 583
Posted By Oliver Micka
Indramat Servo - Open PAR file - How?

Hi everybody, i have back upīs from Indramat Servo Drivers, but those file have suffix PAR.
Drive1.par
Drive2.par

Does anybody know, which program or software i need use to open it and chceck...
Forum: LIVE PLC Questions And Answers June 30th, 2020, 04:09 AM
Replies: 1
Views: 804
Posted By Oliver Micka
MLX1400 and PowerFlex525

Hi all..
I would like create comm between MLX1400 and POWERFLEX 525 trought Ethernet..

I know, answer is a here:
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/52205
...
Forum: LIVE PLC Questions And Answers November 8th, 2019, 05:40 AM
Replies: 1
Views: 503
Posted By Oliver Micka
Siemens KTP Basic - internal Beeper

Hi everyone.
I have question.
Itīs possible control the "internal beeper" in the KTP Basic Panel from PLC Tag ( any tags type ) ?
I would like use that beeper as a signal for "finished the...
Forum: LIVE PLC Questions And Answers August 20th, 2019, 08:21 AM
Replies: 0
Views: 797
Posted By Oliver Micka
1769 SDN - Canīt see adress

Hi Guys.

i have a one production line where is the processor is CompatcLogix L35e, and 2 DeviceNet Scanners.

Today our electricians told me a problem a one position ( 1 from 15, that network...
Forum: LIVE PLC Questions And Answers April 8th, 2019, 07:40 AM
Replies: 3
Views: 555
Posted By Oliver Micka
Conversion from PV550-600 to PV800

Hi everybody..
We have a lot off oldest HMI ( Pv550-600 ). Many HMI is in end of life ( spare parts and repairing is very cost )
We would like replace this type HMI to a new PV800 ( 2711-T7T ) .....
Forum: LIVE PLC Questions And Answers March 4th, 2019, 03:23 AM
Replies: 3
Views: 1,496
Posted By Oliver Micka
Alan, thank for you Reply.. But.. RA...

Alan, thank for you Reply..

But..

RA Answer id 698924:
Answer
To be able to make RUN MODE CHANGE other words online edits in Micro 800 controllers you have to use Connected Component...
Forum: LIVE PLC Questions And Answers March 4th, 2019, 01:04 AM
Replies: 3
Views: 1,496
Posted By Oliver Micka
CCW Developer Edition

Hello guys..

Does anybody know, where i can downloaded this version of CCW ?
Itīs a free or itīs need to purchase ? ( price ? )
Because, we have a lot of Micro 800 PLCīs, and sometimes we need...
Forum: LIVE PLC Questions And Answers January 17th, 2019, 08:05 AM
Replies: 0
Views: 652
Posted By Oliver Micka
PV800 T7T - tag expression.

Hi Guys.
Does anybody idea how can i create " expression" for tags in the CCW for these HMI?

My PLC is SLC500 ( slc 5/04), Communication is only via DH485.
PLC have any data in the INT format (...
Forum: LIVE PLC Questions And Answers August 20th, 2018, 05:24 PM
Replies: 2
Views: 990
Posted By Oliver Micka
Allen Bradley Plc4 microtrol -CMR instruction?

Hello Everybody. We have a too old plc ( allen bradley plc4 microtrol ) which was a run mode until now, but a one pretty morning this plc cannot going to RUN mode.. soo ok, its lifetime is finished.....
Forum: LIVE PLC Questions And Answers June 8th, 2018, 02:41 AM
Replies: 3
Views: 1,047
Posted By Oliver Micka
CompactLogix L35e - Lost Communication.

Hi everybody.
Does anybody know what is the problem, when CLX has lose communication via ethernet every 5-6 months?
CompactLogix have comm between others Compactlogix CPUs and HMIs..

This...
Forum: LIVE PLC Questions And Answers June 16th, 2017, 12:15 PM
Replies: 2
Views: 1,225
Posted By Oliver Micka
ftp://ftp.moeller.net/AUTOMATION/SOFTWARE/SUCOSOFT...

ftp://ftp.moeller.net/AUTOMATION/SOFTWARE/SUCOSOFT/Index.html
Forum: LIVE PLC Questions And Answers May 25th, 2017, 03:36 PM
Replies: 17
Views: 3,311
Posted By Oliver Micka
Talking Jesper.. Solved... It was to easy, when i...

Jesper..
Solved...

It was to easy, when i configured the same network ( laser or cp341 - bits/stop bits/ parity ) laser automaticaly send data do Cp341 because RxD led diode on the card flashed....
Forum: LIVE PLC Questions And Answers May 24th, 2017, 06:46 AM
Replies: 17
Views: 3,311
Posted By Oliver Micka
Hi Jesper.. So I tried configure simatic via...

Hi Jesper..
So
I tried configure simatic via the manual which you sended.
Cp341 are Ok.. No faults.. RX led flashing (tx no ) but when i create the DB and FB (db10,fb7(recieve data),db8,fb8(send...
Forum: LIVE PLC Questions And Answers May 22nd, 2017, 06:51 AM
Replies: 17
Views: 3,311
Posted By Oliver Micka
Jesper.. I use Step7 . many...

Jesper..
I use Step7 .
many thanks..:book::site::beerchug:
Forum: LIVE PLC Questions And Answers May 22nd, 2017, 06:35 AM
Replies: 17
Views: 3,311
Posted By Oliver Micka
Hi Jesper.. Now i have more info from my...

Hi Jesper..

Now i have more info from my laser which have a RS422 com.
This Laser have ASCII protocol.. I think it is a standard serial connection
Showing results 1 to 25 of 59

 