Search: Posts Made By: Baker in Virginia
Forum: LIVE PLC Questions And Answers July 20th, 2021, 03:35 PM
Replies: 2
Views: 802
Posted By Baker in Virginia
EvoLabels Labeler ( Flexwipe ) - Interfacing with ControlLogix

Good Afternoon ,

Thinking of replacing a Labeler with a brand , named EvoLabels ( Flexwipe ).
Sounds like their communication is using Modbus TCP . I know that ProSoft would be an option . Is...
Forum: LIVE PLC Questions And Answers January 25th, 2021, 07:45 PM
Replies: 4
Views: 791
Posted By Baker in Virginia
CompactLogix TON or RTO - Can you change Preset from 100 ms to 100.2 ms , etc.

Good Evening ,

Im using a Shift Register ( BSL ) and Im using a timer to shift these bits .
At the moment my timer is 100 ms , but I would like to have the option to change it to 100.2...
Forum: LIVE PLC Questions And Answers January 13th, 2021, 08:07 PM
Replies: 5
Views: 860
Posted By Baker in Virginia
Yes . I was wondering also , if you can change...

Yes . I was wondering also , if you can change that online .
Forum: LIVE PLC Questions And Answers January 13th, 2021, 04:24 PM
Replies: 5
Views: 860
Posted By Baker in Virginia
Logix 5000-In a Compare How do you display a DINT[313] in Binary ?

Good Afternoon ,

I'm working on a Shift Register , and I have a Tag called ....

Tracking Vision Result
Tag Data Type - DINT [313]

I'm using a Compare Instruction GRT , to activate...
Forum: LIVE PLC Questions And Answers December 30th, 2020, 03:10 PM
Replies: 0
Views: 669
Posted By Baker in Virginia
Banner K50 Indicater Lights and Pro Editor Software. Will not see USB ports

Good Afternoon ,


I'm somewhat new at using the Banner K50 Indicator Lights and Pro Editor Software. I set up one last year and it worked great.


The problem I'm having is communicating...
Forum: LIVE PLC Questions And Answers December 9th, 2020, 08:27 AM
Replies: 6
Views: 2,171
Posted By Baker in Virginia
Powerflex 525 - F 114 uC Fault ( Microprocessor Fault )

Good Morning ,

I have some new Powerflex 525 Drives - This morning I got a F 114 uC Fault. Sounds like it is an issue with the microprocessor . I was able to reset it by powering it down , and...
Forum: LIVE PLC Questions And Answers August 13th, 2020, 08:29 PM
Replies: 23
Views: 4,698
Posted By Baker in Virginia
Thank you all for your thoughts and ideas . We...

Thank you all for your thoughts and ideas . We have our countywide meeting tomorrow , and I will bring up many of your thoughts .

Thanks again ,
Forum: LIVE PLC Questions And Answers August 6th, 2020, 08:36 PM
Replies: 23
Views: 4,698
Posted By Baker in Virginia
County Manufacturing Group- Establishing a Sub Committee to fill the Skills Gap

Good Evening ,


In my hometown we have a Manufacturing Group that gets together once every 2 months to discuss labor issues , the economy , etc.


I suggested getting a sub-committee...
Forum: LIVE PLC Questions And Answers August 1st, 2020, 09:37 PM
Replies: 13
Views: 2,101
Posted By Baker in Virginia
Ok. That is what me and my colleague was thinking...

Ok. That is what me and my colleague was thinking . Would this cause a conflict with Devicenet , and not allow it to control
Forum: LIVE PLC Questions And Answers August 1st, 2020, 08:10 PM
Replies: 13
Views: 2,101
Posted By Baker in Virginia
Good Evening Mr. Roach , Could...

Good Evening Mr. Roach ,


Could anything in Digital Inputs 361 thru 366 cancel out any
communication from Devicenet ? In 363 In 3 we have Jog 1 10.


There is actually no wires on...
Forum: LIVE PLC Questions And Answers July 16th, 2020, 02:06 PM
Replies: 4
Views: 1,126
Posted By Baker in Virginia
Don't have AutoCad . What is the easiest way to convert .DWG to .PDF ?

Good Afternoon ,

I have a few drawings I need to open up. I don't have Autocad. What is the
easiest way to covert .DWG to .PDF ?

Thanks so much in advance .
Forum: LIVE PLC Questions And Answers June 28th, 2020, 07:36 PM
Replies: 5
Views: 1,279
Posted By Baker in Virginia
Nobody knows the password . Once I make some...

Nobody knows the password . Once I make some modifications to the application I will add a go to configure mode button .
Forum: LIVE PLC Questions And Answers June 28th, 2020, 07:08 PM
Replies: 5
Views: 1,279
Posted By Baker in Virginia
Panelview Plus-What is the best way to get back into Config Mode ?

Good Evening ,


I have a Panelview Plus that I need to go back into Config Mode. I understand that if you have a USB keyboard you can press the Default button and go into a screen that will...
Forum: LIVE PLC Questions And Answers June 4th, 2020, 01:49 PM
Replies: 4
Views: 1,325
Posted By Baker in Virginia
Dog Studio 5000- Changing a projects Revision to Ver. 28 from 29.

Good Afternoon ,


I have a Studio 5000 project that I would like to change from version 29 to version 28. I know how to use ControlFlash , and change my controller , but I thought I could go...
Forum: LIVE PLC Questions And Answers May 6th, 2020, 08:57 AM
Replies: 16
Views: 2,880
Posted By Baker in Virginia
Yes , Donvw , Cavanna is the manufacture .

Yes , Donvw , Cavanna is the manufacture .
Forum: LIVE PLC Questions And Answers May 1st, 2020, 07:10 PM
Replies: 16
Views: 2,880
Posted By Baker in Virginia
Thanks . Im having a horrible time finding a...

Thanks . Im having a horrible time finding a Conditioner / Converter with a RTD input to a Type J TC output .

I guess they do not make them ?
Forum: LIVE PLC Questions And Answers May 1st, 2020, 01:12 PM
Replies: 16
Views: 2,880
Posted By Baker in Virginia
Yes Sir . Just looked them up. They are nice. ...

Yes Sir . Just looked them up. They are nice.

Thanks ,
Forum: LIVE PLC Questions And Answers May 1st, 2020, 12:43 PM
Replies: 16
Views: 2,880
Posted By Baker in Virginia
Another question If I use a RTD in the...

Another question

If I use a RTD in the rotating jaw assembly , do they make a conditioner / converter from RTD to Type J ?

If so , could you please send me a link ?

Thanks so...
Forum: LIVE PLC Questions And Answers May 1st, 2020, 11:47 AM
Replies: 16
Views: 2,880
Posted By Baker in Virginia
I like all your ideas - How small do...

I like all your ideas

- How small do wireless temperature transmitters come ? Do you have
any recommended brands or models ?

- drforsythe - " They were sealed and the...
Forum: LIVE PLC Questions And Answers May 1st, 2020, 10:00 AM
Replies: 16
Views: 2,880
Posted By Baker in Virginia
Dog Using a Slip Ring for Type J Thermocouples-Any history of issues for any of you guys?

Good Morning ,

We have a new packaging machine that have Slip Rings . We are using the Slip Rings for a rotary jaw assembly that has heaters installed. We don't have much problem with the...
Forum: LIVE PLC Questions And Answers April 29th, 2020, 10:05 AM
Replies: 4
Views: 968
Posted By Baker in Virginia
Thanks you so much . Why does Rockwell keep...

Thanks you so much . Why does Rockwell keep changing their website ? It certainly doesn't seem easier .

Thanks again,
Forum: LIVE PLC Questions And Answers April 29th, 2020, 09:39 AM
Replies: 4
Views: 968
Posted By Baker in Virginia
Me

Me
Forum: LIVE PLC Questions And Answers April 29th, 2020, 09:24 AM
Replies: 4
Views: 968
Posted By Baker in Virginia
FactoryTalk View Runtime Software - Number of Screen Packages

Good Morning ,

Several years ago I would use Hope Industrial Monitors , with a PC , and Rockwell Automation FactoryTalk View Runtime Software . It would come in software packages of 15 display...
Forum: LIVE PLC Questions And Answers March 31st, 2020, 01:38 PM
Replies: 19
Views: 2,107
Posted By Baker in Virginia
Thanks for all your ideas . I love the Fluke...

Thanks for all your ideas . I love the Fluke DataPaq option . What is the rough price of the TP3116 10 Channel ?

"We use Datapaq Oven Trackers for validating temperatures of paint curing ovens....
Forum: LIVE PLC Questions And Answers March 31st, 2020, 12:29 PM
Replies: 19
Views: 2,107
Posted By Baker in Virginia
Dog Do you know of any High Temperature Logging 600 Degrees F

Good Afternoon ,

Would you folks know of any High Temperature logging systems that
would record , and handle up to 600 - 700 Degrees Fahrenheit ? MicroDaq , Onset , etc. would not handle...
Showing results 1 to 25 of 305

 