Search: Posts Made By: Chris Taylor
Forum: LIVE PLC Questions And Answers September 13th, 2021, 08:47 AM
Replies: 19
Views: 1,040
Posted By Chris Taylor
qwemx have you made sure that the mag pickup...

qwemx
have you made sure that the mag pickup is as close to the teeth as possible <0.2mm, this will increase voltage output significantly. If that fails, use a proximity sensor
Forum: LIVE PLC Questions And Answers July 23rd, 2021, 06:32 AM
Replies: 28
Views: 4,851
Posted By Chris Taylor
Cardosocea you forgot the free training at IA's...

Cardosocea you forgot the free training at IA's Inductive University https://inductiveuniversity.com/
Forum: LIVE PLC Questions And Answers July 7th, 2021, 10:35 AM
Replies: 41
Views: 4,540
Posted By Chris Taylor
https://marineindustrialmachinery.com/images/produ...

https://marineindustrialmachinery.com/images/product/cache/crouzet-3-xd-26-plc-controller-17536412001592292985-818x818.jpg818 ◊ 818...
Forum: LIVE PLC Questions And Answers June 24th, 2021, 11:47 AM
Replies: 19
Views: 2,096
Posted By Chris Taylor
I tend to use Advanced ip scanner, its free and...

I tend to use Advanced ip scanner, its free and can be run without install. shows MAC addresses, manufacturer if it can and device name to which all useful


...
Forum: LIVE PLC Questions And Answers February 24th, 2021, 10:17 AM
Replies: 8
Views: 1,429
Posted By Chris Taylor
Nick If your machines are connected or...

Nick


If your machines are connected or could be, then Ignitions enterprise functions could make remote management / upgrades / support etc a breeze.
Theres a few UK integrators and we are...
Forum: LIVE PLC Questions And Answers February 10th, 2021, 03:49 AM
Replies: 0
Views: 533
Posted By Chris Taylor
Modbus TCP sounder

Morning all.


Iím looking for a simple sounder (adjustable volume), perhaps with a single beacon that can operate as a Modbus TCP slave, POE even better.
Iíve seen the Patlite L6A but its...
Forum: LIVE PLC Questions And Answers January 14th, 2021, 06:46 AM
Replies: 9
Views: 1,364
Posted By Chris Taylor
Thereís a divide in our business due to Covid,...

Thereís a divide in our business due to Covid, manufacturing SCADA and MES has slowed, although demand for remote monitoring, especially mobile friendly executive dashboards has increased. For our...
Forum: LIVE PLC Questions And Answers December 17th, 2020, 08:30 AM
Replies: 5
Views: 952
Posted By Chris Taylor
It sure looks like it itsgowribe ...

It sure looks like it


itsgowribe


Try breaking the ring between the NOCs to see if that clears the faults, it might eliminate any ring issues, as tragically1969 says, sometimes Moxas don't...
Forum: LIVE PLC Questions And Answers November 6th, 2020, 10:24 AM
Replies: 7
Views: 1,129
Posted By Chris Taylor
Above and beyond Parky We have Kepware...

Above and beyond Parky


We have Kepware setup as TCP, using the Mitsubishi Ethernet Driver, are you using the Mitsubishi FX Net Driver?


I won't get to site for a couple of weeks, but I will...
Forum: LIVE PLC Questions And Answers November 5th, 2020, 12:17 PM
Replies: 7
Views: 1,129
Posted By Chris Taylor
Thanks all Parky, I'll try a UDP...

Thanks all


Parky, I'll try a UDP connection,

Are you saying that they didn't have to setup a port? in any event I can setup a spare channel.
Forum: LIVE PLC Questions And Answers November 5th, 2020, 05:24 AM
Replies: 7
Views: 1,129
Posted By Chris Taylor
Mitsubishi FX3u-ENET port question

Good morning all

I've inherited a PLC system that has two Q01 and 6 FX2n PLCs
The FXs have a FX3u-ENET module.
There is quite a bit of PLC to PLC data exchange and all of that is...
Forum: LIVE PLC Questions And Answers October 22nd, 2020, 03:25 PM
Replies: 24
Views: 5,212
Posted By Chris Taylor
Except it doesn't support the Ethernet port!!

Except it doesn't support the Ethernet port!!
Forum: LIVE PLC Questions And Answers October 14th, 2020, 07:10 AM
Replies: 7
Views: 1,084
Posted By Chris Taylor
Not two port, but I've used the Moxa EDR-810s as...

Not two port, but I've used the Moxa EDR-810s as firwalls before, useful as they have NAT translation as well.
Forum: LIVE PLC Questions And Answers July 22nd, 2020, 08:34 AM
Replies: 3
Views: 1,502
Posted By Chris Taylor
Yes, so long as your CLX's have a couple spare...

Yes, so long as your CLX's have a couple spare connections available on the Ethernet card and there is overhead on the processor for additional comms it should work just fine. its a simple thing to...
Forum: LIVE PLC Questions And Answers July 3rd, 2020, 12:18 PM
Replies: 3
Views: 1,280
Posted By Chris Taylor
Kidblue Well thats simple, thanks for the...

Kidblue


Well thats simple, thanks for the offer, but I'll make one tonight.
Forum: LIVE PLC Questions And Answers July 3rd, 2020, 11:01 AM
Replies: 3
Views: 1,280
Posted By Chris Taylor
ProSoft Null Modem Cable (Cable 15)

I have to reprogamme a Prosoft MVI56MCMR and I cant find my programming lead.


Would anyone have the pin out please.. as I can't find the details at ProSoft



RJ45 one end, 9 pin din the...
Forum: LIVE PLC Questions And Answers June 6th, 2020, 01:18 PM
Replies: 12
Views: 2,172
Posted By Chris Taylor
Garath Really consider an OT network...

Garath


Really consider an OT network that just connects to your machines and devices. Then have a single point of connection between OT and IT such as a SCADA or MES.

For NAT in an OT...
Forum: LIVE PLC Questions And Answers June 5th, 2020, 12:25 PM
Replies: 6
Views: 1,780
Posted By Chris Taylor
I don't pretend to konw anything about you...

I don't pretend to konw anything about you situation Darren but this is so very typical of British Companies, the budget for this kind engineering is always small but they expect "you" the engineers...
Forum: LIVE PLC Questions And Answers January 16th, 2020, 11:36 AM
Replies: 2
Views: 1,013
Posted By Chris Taylor
From Ignitions Forum Tag properties (with...

From Ignitions Forum


Tag properties (with the exception of certain alarm properties) can’t use expression bindings, only bindings to UDT parameters. The reason the editor is there is in case...
Forum: LIVE PLC Questions And Answers December 12th, 2019, 03:27 AM
Replies: 16
Views: 2,130
Posted By Chris Taylor
Sham More info required. Cell binding is...

Sham


More info required. Cell binding is only useful for a static number of pens, if you want to hide a pen you could cell bind to that as well. For really dynamic pen sets its better to create...
Forum: LIVE PLC Questions And Answers December 11th, 2019, 07:35 AM
Replies: 16
Views: 2,130
Posted By Chris Taylor
Like this for example? ...

Like this for example?


https://www.bijc.co.uk/img/cell.PNG
Forum: LIVE PLC Questions And Answers December 11th, 2019, 04:58 AM
Replies: 16
Views: 2,130
Posted By Chris Taylor
I understand what you are doing, If you...

I understand what you are doing,


If you are using indirection or "cell binding" on the "TAG_PATH", prehaps you could use indirection on the "NAME" as well.
Forum: LIVE PLC Questions And Answers December 11th, 2019, 04:53 AM
Replies: 27
Views: 4,784
Posted By Chris Taylor
I use the Moxa ioLogik E1200 range, supports...

I use the Moxa ioLogik E1200 range, supports Modbus and EtherNetI/P

...
Forum: LIVE PLC Questions And Answers August 21st, 2019, 05:31 AM
Replies: 28
Views: 5,018
Posted By Chris Taylor
I do hope you have a long evening available. ...

I do hope you have a long evening available.
Ignition is a fully featured SCADA platform that can be expanded to doÖ well anything Iíve asked it to do.
KepwareEX is a OPC server with various...
Forum: LIVE PLC Questions And Answers August 21st, 2019, 05:20 AM
Replies: 28
Views: 5,018
Posted By Chris Taylor
Really! its easy, have you tried the Kepware...

Really! its easy, have you tried the Kepware website


https://www.kepware.com/en-us/products/kepserverex/


Click the button marked "Download Free Demo"