Forum: LIVE PLC Questions And Answers July 20th, 2021, 04:56 PM
Replies: 3
Views: 884
Posted By Saulo35
RedLion Crimson 3.1 - Project Variables Sort

Hi,

Does anybody know how to sort the "Project Variables" under "Control"?

Please see screen capture attached.

Thank you
Forum: LIVE PLC Questions And Answers March 12th, 2021, 07:28 PM
Replies: 10
Views: 1,866
Posted By Saulo35
JesperMP, regarding your suggestion "Teamviewer...

JesperMP, regarding your suggestion "Teamviewer has an integrated VPN server. Have you seen this guide?", the TeamViewer manual says, under 8.2: "If you connect your local computer to the remote...
Forum: LIVE PLC Questions And Answers March 12th, 2021, 06:49 PM
Replies: 10
Views: 1,866
Posted By Saulo35
Yes, that was the intention - to make the Office...

Yes, that was the intention - to make the Office #1 PC believe that a certain "reachable" IP address - in this case, 127.0.0.1 - was , in fact, the Site's internal IP address 192.169.0.11....
Forum: LIVE PLC Questions And Answers March 11th, 2021, 02:36 PM
Replies: 10
Views: 1,866
Posted By Saulo35
Thank rQx and JesperMP, I will investigate the...

Thank rQx and JesperMP, I will investigate the information you provided and report back.

Regarding the installation of eW*n on site, I am somewhat limited to what I can get done on site, but I...
Forum: LIVE PLC Questions And Answers March 10th, 2021, 06:52 PM
Replies: 10
Views: 1,866
Posted By Saulo35
Siemens S7-1200 Remote Access

Hi,

Here is my dilemma - I hope somebody has done this before. This involves equipment in three different locations (and countries).

On site:

Two Siemens S7-1200 PLCs, connected via...
Forum: LIVE PLC Questions And Answers February 17th, 2021, 04:15 PM
Replies: 3
Views: 593
Posted By Saulo35
Thank you AkaHammer, you are right and I am...

Thank you AkaHammer, you are right and I am already reading data from the VFDs such as "Drive Status 1" (0020H) and Output Current (0026H). What I don't know is how to read parameters. For instance,...
Forum: LIVE PLC Questions And Answers February 17th, 2021, 04:07 PM
Replies: 5
Views: 639
Posted By Saulo35
Thank you, GaryS - I believe, in your case, the...

Thank you, GaryS - I believe, in your case, the PC running DriveWizard had an RS485 card or adapter directly connected to the drives, right?
Forum: LIVE PLC Questions And Answers February 17th, 2021, 02:08 PM
Replies: 5
Views: 639
Posted By Saulo35
Yaskawa DriveWizard via Opto 22 Serial Module

Hi,

Does anybody know if it is possible to run Yaskawa's DriveWizard software on a PC, to monitor and configure V1000 VFDs that are connected to an Opto 22 Serial Card (i.e., the VFDs are not...
Forum: LIVE PLC Questions And Answers February 17th, 2021, 02:02 PM
Replies: 3
Views: 593
Posted By Saulo35
Yaskawa V1000 VFD - How to read parameters vis Modbus

Hi,

I have several Yaskawa V1000 VFDs connected via Serial Modbus to Opto22 serial modules. Everything is sort of working. I was able to set frequency references, start and stop motors, etc.
...
Forum: LIVE PLC Questions And Answers August 13th, 2020, 05:27 PM
Replies: 1
Views: 781
Posted By Saulo35
FactoryTalk View ME w/Multiple PLCs - Communications Monitoring

Hi,

I would like some help in figuring out (1) how to monitor communications between a PanelView and multiple PLCs, and (2) what to do, if a PLC is down, to avoid bogging down the rest of the...
Forum: LIVE PLC Questions And Answers August 13th, 2020, 01:31 PM
Replies: 9
Views: 2,405
Posted By Saulo35
I want to add the following regarding janner_10's...

I want to add the following regarding janner_10's comment: this HMI is wired to 5 identical PLCs, each controlling 1 machine. If the recipe management is moved to the PLCs, then, when the user...
Forum: LIVE PLC Questions And Answers July 21st, 2020, 11:44 AM
Replies: 8
Views: 11,007
Posted By Saulo35
Glad to report that I have 5 slightly different...

Glad to report that I have 5 slightly different .RSS programs running on RSLogix 500 Emulate (each on its own node), and I am able to access them online from RSLogix 500, and I have a FactoryTalk...
Forum: LIVE PLC Questions And Answers July 15th, 2020, 08:24 PM
Replies: 4
Views: 2,073
Posted By Saulo35
Wow. Thank you OG. It worked perfectly. I didn't...

Wow. Thank you OG. It worked perfectly. I didn't know RSLogix 500 Emulate could run more than one program. In the meantime I found that if I renamed the OPC Server in FactoryTalk to anything other...
Forum: LIVE PLC Questions And Answers July 13th, 2020, 07:16 PM
Replies: 4
Views: 2,073
Posted By Saulo35
Hi seyednima, I have almost the same situation as...

Hi seyednima, I have almost the same situation as you do. All my 5 MicroLogix will run the same PLC program. I tried running just one instance of RSLogix 500 Emulate, but creating several DDE topics...
Forum: LIVE PLC Questions And Answers July 13th, 2020, 07:07 PM
Replies: 1
Views: 4,330
Posted By Saulo35
I get that error while attempting the following: ...

I get that error while attempting the following:

My FT View ME (11.0) application is intended to communicate with 5 MicroLogix 1400PLCs
All PLCs will be running the same program
I am running...
Forum: LIVE PLC Questions And Answers July 4th, 2020, 06:57 PM
Replies: 9
Views: 2,405
Posted By Saulo35
janner_10, my client has a more or less...

janner_10, my client has a more or less "standard" PLC program and for some reason he switches HMIs from time to time. So, if possible, he would like to leave the PLC program alone.
Forum: LIVE PLC Questions And Answers July 4th, 2020, 12:02 PM
Replies: 9
Views: 2,405
Posted By Saulo35
Thank you. I finally discarded both Recipe Plus...

Thank you. I finally discarded both Recipe Plus and Recipe 2 ActiveX. I defined a capacity of 64 recipes. I created a page that shows 8 recipes at a time. There are buttons and macros to advance to...
Forum: LIVE PLC Questions And Answers June 22nd, 2020, 10:29 AM
Replies: 9
Views: 2,405
Posted By Saulo35
Thank you JZerb and sigmadelta, I will do a last...

Thank you JZerb and sigmadelta, I will do a last effort to implement, via Macros, something to emulate this:

With a known x,

Tag1 = Tag2[x] (not possible in FTVS)

Emulate that with

If x =...
Forum: LIVE PLC Questions And Answers June 21st, 2020, 05:03 PM
Replies: 9
Views: 2,405
Posted By Saulo35
I must add, modifying the PLC programs of the...

I must add, modifying the PLC programs of the machines (to implement the indirect addressing and recipes there) is not an option.
Forum: LIVE PLC Questions And Answers June 20th, 2020, 07:55 PM
Replies: 9
Views: 2,405
Posted By Saulo35
FactoryTalk View ME Recipes

Hi,

I want to share where I am right now, to see if I am missing something.
I am using FactoryTalk View Studio Machine Edition, Version 11.00.

I have 5 identical machines. Each can run a cycle...
Forum: LIVE PLC Questions And Answers June 5th, 2020, 02:34 PM
Replies: 3
Views: 1,587
Posted By Saulo35
Today, after I received the Opto 22 EPIC...

Today, after I received the Opto 22 EPIC GRV-CSERI-4 serial communication module, I am happy to report that I was able to establish RS-485 communication between the EPIC PR1 processor and the...
Forum: LIVE PLC Questions And Answers May 20th, 2020, 01:46 PM
Replies: 0
Views: 714
Posted By Saulo35
Opto22 PAC Display Configurator Pro - Alarm Import

Iím finishing up a PAC project and one of the the last things I need to take care of is setting up all of my alarm points in PAC Display Configurator Pro 10.2d Build 0040 (December 19th, 2019).

To...
Forum: LIVE PLC Questions And Answers February 6th, 2020, 01:10 PM
Replies: 3
Views: 1,587
Posted By Saulo35
Thank you. In the meantime, I found that...

Thank you. In the meantime, I found that PowerFlex 525 accepts only a limited set of Modbus commands, over RS-485, not Ethernet/IP.
Forum: LIVE PLC Questions And Answers January 20th, 2020, 10:13 PM
Replies: 0
Views: 579
Posted By Saulo35
MAPware 7000: Numeric Keypad Simulation Does not Work

Hi,

When simulating my project, calling a numeric keypad causes MAPware 7000 to slow down to a crawl, and the keypad does not accept keys pressed. The numeric keypad's "display" varies between...
Forum: LIVE PLC Questions And Answers December 30th, 2019, 08:10 PM
Replies: 3
Views: 1,587
Posted By Saulo35
PowerFlex 525 and Opto 22

Hi,

Has anybody controlled and monitored a PowerFlex 525 VFD using Opto 22's PAC Control? The client is still undecided between EPIC or staying with SNAP/PAC, but it should be irrelevant since the...