Micrologix & Mettler Toledo

Micrologix 1400 has a DFI port can do rs232 to Mettler Toledo IND560
Use this RS232 high impedance cable between them. Black Box EMN04A-1000. Good up to 500 feet.
I believe Rockwell has a typical code library for bringing in asc2 data.

I think people have done the ethernet interface but not sure if its reliable versus the rs232.
 

Similar Topics

Hi everyone, have anyone of you familiar with IND560 weighing scale communicating with micrologic 1400.
Replies
6
Views
3,719
I am currently backing a Micro Logix 1100 and no-one seems to have the file for me to upload from. Is there a way for me to upload the project off...
Replies
15
Views
337
Hi, I am working with a Micrologix 1400 model 1766-L32BXB. With no input wires connected to the “in12” thru “in19”, I am getting 24 volts while...
Replies
4
Views
172
I am trying to set up a read message in a MicroLogix1100 to read the value of a DINT in a ControlLogix5561. I have successfully set up a message...
Replies
2
Views
162
Hi everyone, I hope I don't butcher this up, please feel free to critique me wherever if I do, I have an issue I would equate to "chasing...