RSview 4.00 and Microsoft Virtual PC

SirScott

Member
Join Date
Jan 2008
Location
TROY, Ohio
Posts
6
I have an issue where I have to creat and modify RSView ME 4.00 applications but I have RSview 5.00 on my PC. Since I can't have both versions installed, I created a Virtual PC using Microsoft Virtual PC and loaded RSview Studio ME version 4.00. Everything works except I can't Restore or
Backup the application to or from the .APA file. When I try, I get the message"

"Unable to create the archive .... Please check that the application is not open elsewhere."

Of course it is not open, it is some issue with compatablility with the Application Manager and the Virtual PC.

Anyone have any suggestions
 
FactoryTalk View Studio V5.xx can generate runtime applications for RSView ME 4.0, 3.2, 3.1 and 3.0. Therefore, there is no need to have multiple versions of RSView Studio.
 
Unfortunately, my customer requires the .APA file to be in revision 4.00, not just the .mer file. This is so they can support it with there 4.00 software and they are not willing to upgrade. Once you open up a rev 4.00 application in 5.00 or higher, it can't be converted back to 4.00.

I did, however resolve my problem. When I installed the RSView ME 4.00 on my virtual PC, I did not install the RSLinx Enterprise. This somehow prevented the Application manager from working. Installed RSView enterprise and problem is resolved.

Thanks for the reply!
 

Similar Topics

Hello fellow wirenuts, I am looking to find the P.B. touch indicator option on version 13.00 and failing. It has been a year or so since I last...
Replies
9
Views
291
Hello, I have converted RSView 32 to FTView SE 14 (I have tested FTView 12 before as well and there were some difficulties so I moved on to...
Replies
4
Views
248
Okay, something I have not seen before.. RSView SE. I am working on an existing project. There is a value the customer wants trended and it is...
Replies
4
Views
807
I have a request to integrate a pause button in RSlogix to be able to start/stop a video. Video format is not defined at the moment, so it could...
Replies
2
Views
794
Hello everyone, I am having a problem with conversion from RSView32 to FT View SE Local project on version 12.00 (CPR 9 SR 12). Firstly, I have...
Replies
6
Views
1,404
Back
Top Bottom