More people could look at this program if you printed it to a PDF file, including both the Program Files and Data Files; see the attached image.Here is a zip file of the program
yes, 24h, of course.Adsorb COUNTER is set 24 hours (1440 minutes). Adsorb counter starts counting at the beginning of steaming on either bed and runs concurrently with steam, purge, & cooling counters. Once cooling is complete (and you are in idle) the bed continues to adsorb until either the adsorb counter counts to 1440 OR Excess PPM switches the bed depending on the "Timed/Monitor" selector switch in the step advance rung.
On that Report Options dialog menu, click Deselect All, then check the Program Files and Data Files boxes, then click Print; that should make for a smaller PDF file.RSLogic 500 (or at least the version I have) won't let me print to a PDF. I printed and copied to PDF but this site says it's too large to attach. I did attach a zip file of the program.