Yet another RSLogix 5000 vs Studio 5000 thread

harryting

Lifetime Supporting Member
Join Date
May 2002
Location
Puget Sound
Posts
2,595
Ya, I know. My search ability (google-fu) is lacking today.

While downloading a bunch of updates from RA today I started to wonder about going to the "Studio" environment which I read from some threads that some of the basic functionality change makes things quite different. Currently, the most up to date version we have is version 20. My main concern is to be able to support the older versions I still have running out there, going back to version 16 or older on the same laptop. I also heard about how the new RSLinx that works with studio handles EDS differently so that's a concern as well.

Any words of wisdom? Or maybe someone can point me to another thread where this has already been answered. Thanks,
 
Of the older versions I keep only version 16 and 20 installed. Version 16 because that was where the L55s stopped, and V20 because that was where the L6x and older CompactLogix stopped. Everything is kept updated as far forward as it can go, so I only need to install the three versions.

A year ago I actually had everything at V20, till we did a project on the cheap this summer and recycled an old L55.
 
Last edited:
I have both Studio 5000 (V21) and RSLogix5000 V20 installed on the same VMware image running Windows 7 Pro and don't have any issues.

I haven't been on Studio 5000 for long and I had to back track to V20 on a project because to my surprise the FactoryTalk Alarms were not supported in V21. Apparently they are back in the new version but I haven't installed it yet.
 

Similar Topics

So, after adding a second PC, purchasing another server license and setting up to function as a redundant server for FTV SE, I think I've...
Replies
2
Views
2,176
Howdy, Summary Rank beginner here. I don't have anything more than [RSLogix Micro Starter Lite], so I am using that for it's editing...
Replies
23
Views
4,861
What software are you using or would recommend for drawing interlock, control and sequence diagrams? A full blown CAD feels over the top to me...
Replies
10
Views
3,232
Hey Folks. Once again. I have an issue with CCW on my laptop. This is getting old, really...... I like the software but... Seems like every time...
Replies
23
Views
7,275
This may very well be my last question. I'm not on to system alarming. Each station has its own set of alarms. What I have done is provide a list...
Replies
5
Views
2,400
Back