Hello friends,
i am using gx works2 in Mitsubishi q series Plc.i have 3 plcs in panel which devides in program in 3 parts i want to know how i can i stop the motor whose programming done in 1st plc. but due to some programming reasons i want to stop it from 2nd please, please tell me how to take the reference. suppose y2 is my motor(present in 1st plc) want to off with x5 (present in second plc) How to take reference from other plc?????????????????????? ![]() please help as soon as possible............... |
![]() |
![]() |
#2 |
Lifetime Supporting Member + Moderator
|
Posting the same question in four threads won't get a response any faster. All it will do is cause confusion as different people post their answers in different threads.
Program the X5 signal to control a discrete output in PLC#2. Wire that output to an input in PLC#1 and include that input in PLC#1's control of the motor. |
![]() |
![]() |
#3 |
Member
![]() ![]() Join Date: Feb 2021
Location: melborn
Posts: 25
|
thanks for your valuable reply.....
is it possible without hardware changes..........like any mutaul memory bit or somthing else..................... thanks |
![]() |
![]() |
#4 |
Member
|
What sort of links have you between the PLC's is it NETH, Ethernet or are you using digital I/O, need more information.
|
![]() |
![]() |
#5 |
Member
![]() ![]() Join Date: Feb 2021
Location: melborn
Posts: 25
|
using ethernet for communication ........and cc link for ios
|
![]() |
![]() |
#6 |
Lifetime Supporting Member
![]() ![]() Join Date: Feb 2015
Location: Yokohama
Posts: 490
|
If you have available CC-Link IO in all of these PCS, why can't you implement the suggestion from Steve Bailey in post # 2 above? Using Ethernet will be far too much more complex.
|
![]() |
![]() |
#7 |
Member
![]() ![]() Join Date: Feb 2021
Location: melborn
Posts: 25
|
all plcs are communication through ethernet..........
and now i want to use memory bit of 1 plc in plc 2 ... that it how can i make the memory bit like m345 global |
![]() |
![]() |
#8 | |
Lifetime Supporting Member
![]() ![]() Join Date: Feb 2015
Location: Yokohama
Posts: 490
|
Quote:
The Melsec TCP specification allows reading and writing of elements in remote PCLs, but you do have to configure properly all the Ethernet parameters in all processors and then write the correct program. |
|
![]() |
![]() |
#9 |
Member
![]() ![]() Join Date: Feb 2021
Location: melborn
Posts: 25
|
thank you
|
![]() |
![]() |
#10 |
Member
|
Perhaps this manual will contain what you need
http://www.atronika.com/Mitsubishi/P...ernet-Port.pdf |
![]() |
![]() |
#11 |
Member
![]() ![]() Join Date: Feb 2021
Location: melborn
Posts: 25
|
thanks brother
|
![]() |
![]() |
Bookmarks |
Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
Thread Tools | |
Display Modes | |
|
|
![]() |
||||
Thread | Thread Starter | Forum | Replies | Last Post |
Mitsubishi GX Works2 Structured Text: Logical NOT not working | Panther | LIVE PLC Questions And Answers | 1 | September 22nd, 2017 06:05 AM |
GX Works2 vs GX Works3 | gleblanc | LIVE PLC Questions And Answers | 3 | March 28th, 2016 12:17 PM |
Is it mpossible to update GX WORKS2 from IQ WORKS? | sykrising | LIVE PLC Questions And Answers | 0 | November 4th, 2014 07:18 PM |
Introduction + Questions GX DEV / WORKS2 /FX1n | Michael Somnes | LIVE PLC Questions And Answers | 4 | January 15th, 2014 03:42 PM |
GX Works2 | yngbld13 | LIVE PLC Questions And Answers | 2 | May 14th, 2013 04:16 PM |